  1. K

    Wireless alarms

    Hi guys What is the best wireless alarm on the market? I always fit hard wired alarms but on this job I can't, I'm not to bothrr Thanks ,
  2. K

    Nest v3 - Help with existing wiring

    This is not having a dig but if you don't no what your doing give a heating engineer or an electrician a call its not worth the risk of blowing it up or yourself All the best
  3. K

    Fire alarm courses

    Much appreciated
  4. K

    Fire alarm courses

    Bit of advice would be much appreciated I'm currently a fully qualified electrician , approved contractor with niceic etc I want to start installing fire alarms conventional and addressable , I have installed many conventional systems but not addressable, done a couple of minor courses...
  5. K

    micc cable

    hello all can anybody tell me what amps micc cable can carry clip direct 1.5 2 core 2.5 4 core thanks
  6. K

    Change key pad from led to LCD

    Hi all Got a accenta alarm system with desperate key pad which is an led keypad , I have change the keypad to LCD but it powers up ect , recognisers the code but dose not let you set alarm Any help would be great. Cheers
  7. K

    user manual

    hi all I have just installed the firesafe dual guard+ 2 wire 4 zone fire alarm system nut have lost the user manual :? any of you guys have one as I cant find on google ect?
  8. K

    emergency lighting

    :roll: whats best?
  9. K

    emergency lighting

    hi all I want to wire 4 x 2d fittings with emergency built in them with 4 x pir sensors so they all come on together when any of the pir,s r detected, and key switch of course many thanks any diagrams or advice would be great
  10. K

    kva

    many thanks for all your advice guys so if I need 4 x 60 amp supplys do I calculate the following 60x4 =240x230 then divide by 1000= 55.2kva is that correct? /
  11. K

    kva

    no gas in property the flats are not very big either, would you recommend 60 amp supplys? what would be the total kva for 4 flats? :D
  12. K

    kva

    I am going to need 80/100 amp supply to each flat and I only have 1 supply at present, and they have asked me what kva I will need I am not sure so any help or advice would be much appreciated thanks
  13. K

    kva

    any help would be grateful I am turning a house into 4 flats I am going to need 4 x100 amp supplys as I am having electric showers cookers, storage heaters ect the supply company has asked what kva I will need, but im not sure any advice would be fantastic
  14. K

    best wireless alarms

    hi all what is the best wireless house alarm on the market or any recommendations?
  15. K

    wiring a external bt bell

    hello all, how to wire a bt external 80d bell to a rj45 phone point?
  16. K

    bt external bell 80d wiring

    evening all I need to wire a bt external bell to a phone system I no how to connect to a standard bt socket, but I want to connect it to a rj45 phone socket, but don't no what connections are what can anyone help?
  17. K

    outdoor flex

    i have a rcd fuse spur in my garage, from the rcd fuse spur swa going to a wiska box at the other end of the garden, i want to put two post lights in the garden about 5 meters from the wiska box, can i flex out of the wiska box with flex or is it not allowed?n there is nothing wired off the...
  18. K

    alarm code

    thank you very much............alarm
  19. K

    alarm code

    you no what i meant........ alarm or whatever you call youself
  20. K

    alarm code