  1. S

    Boiler Problems

    the rad is leaking again, that don't sound promising for a start, lets face it fitting a rad without leaks ain't hard, if your pressure is good coming out the cold tap, i personally think it sould be simular coming out the hot
  2. S

    PowerMax 155 Whistling

    im a powermax specialist :cry: poor bloke
  3. S

    powermax 155

    knew she was there somewhere:) remember that 1, they can be tricky to find
  4. S

    What is the Law?

    shut ya trap and get ya wallet out :lol:
  5. S

    Water only hot when heating is on!

    when u turn the tap on does the flow pipe below the boiler, going to the heating, get warm? if so probably the diverter valve
  6. S

    Furred up pipes

    cut out all the parts of the pipe what u would consider to be very blocked, most of the time the scale will only block the cold feed from the header tank down to where it meets the system, add some scale remover, make sure u drain down some of the system, dont just add it into the tank, lever...
  7. S

    powermax 155

    just simply a button located somewhere on the boiler, i would be quite clear in the instructions
  8. S

    powermax 155

    sorry i cant get any pics or boiler spec for that boiler/model, and i dont know what its features are of the top of my head, only thing i can sagest is that u look up, reset button in the instructions did u turn the power off before u drained down?
  9. S

    Noisy Combi Protherm

    does sound like a quality machine :lol:
  10. S

    powermax 155

    who makes the boiler so i can get up the spec for it, im assuming all the controls are calling for heat, eg the programmer is switched on and the room stat turned up
  11. S

    keston celsius c25

    tell him no, stick with the more popular models, worcester vaillant potterton baxi etc, if nothing else it will be easier to get parts, ow and no condencing boilrs :)
  12. S

    Noisy Combi Protherm

    fan or air in the system! did u flush the old system through? i think if u need to ask u probably shouldn't be installing.;)
  13. S

    powermax 155

    all the rads are full and u are getting water out the bleed valves? the header tank is full ? u can also bleed the system at the pump, ( undo the big screw on the front) if your sure the system is full do u have power at the boiler? (power light on) i u didnt switch the power off...
  14. S

    Baxi Barcelona Lockout

    i went to install my uncle a boiler the other day, turned up and funny thing was, he was standing there with a big smile on his face looking all prowed with his new potterton condencing boiler sitting next to him, stright bk to the shop it went, ended up with a worcester:) non condencing:)...
  15. S

    powermax 155

    does your boiler have a piolt light? if so did u turn it off before u drained down, could have gone on overheat lockout
  16. S

    Airing cupboard ventilation requirements

    if u have a look in the installation instructions it will say if/how much ventilation u require, if its a room sealed appliance there is a chance i may not even need ventilation.
  17. S

    Baxi Bahama heat exchanger fault

    powerflushing yer great :roll:
  18. S

    Replacing PCB on a Biasi

    but although u cant do this by law, its a nice easy job, as long as the someone doing the job was to make sure there was no power at the boiler, and used a bit of comon sence :)
  19. S

    Vaillant combi - no hot water

    :D u have a merry christmas cleaning that valve then, still wont work without the new diaphramme your gona need to go in it
  20. S

    tripping out

    your sure the boiler has 1 - 1.5 bar pressure? its possible the heatexchanger could be slightly blocked and after a period of time it goes out on overheat