  1. B

    Hive connection to Worcester 30i

    Just as an update to this. Nothing changed with my wiring. I just didn`t "click" the back plate on correctly so now I did and all is running ok. So, for any others looking at this, for my setup, I needed to link L and 1 on the Hive receiver back plate. Thanks for the advice and confirmation...
  2. B

    Hive connection to Worcester 30i

    Old controller is back on and everything working ok. I`m going to try again tomorrow.
  3. B

    Hive connection to Worcester 30i

    Just wondering, I assume link wire between L and 1 is needed (as this was set up on the original connection)???
  4. B

    Hive connection to Worcester 30i

    There are no other components i.e timers, controller etc.
  5. B

    Hive connection to Worcester 30i

    Thanks. Yes it is
  6. B

    Hive connection to Worcester 30i

    Thanks. Yes. Thanks. Yes it is a single. I`ll strip some more cable back like you say. Earth was never connected on old receiver, hence left as is.
  7. B

    Hive connection to Worcester 30i

    Hi, I have managed to install a Hive ok to my combi boiler (Worcester 30i). However the heating will not come on. Tried a boost, and increasing temp on thermostat, but heating will not start. My hub, receiver are all connected up ok. Attached is the wiring (old unit, and new Hive). Does this...
  8. B

    Optima G3 Tamper LED

    Hi. I am trying to test my alarm (G3). But when I enter the "PROG" and code (user), only the TAMPER led lights up (and not BOTH the TAMPER and DAY Leds as the manual says). . I`ve taken the panel off, entered code to silence panel, and reset and checked wiring). This resets to just DAY mode as...
  9. B

    Underfloor heating RCD tripping

    Thanks. It`s cheap enough to replace first so I will try that and then move on. I can do this, but anything else will require special equipment and testing. I know that all resistances were checked before, after installation including sensor probe and all were within tolerances. Nothing has been...
  10. B

    Underfloor heating RCD tripping

    The power is only "off" on the thermostat controller (i.e. in a state where it is not supplying power to the UFH) and not by any isolation switch. And so, when the RCD trips, the whole thermostat is isolated. Thanks
  11. B

    Underfloor heating RCD tripping

    Sorry, to be clear the RCD supplies the thermostat that then supplies the UFH.
  12. B

    Underfloor heating RCD tripping

    Could this be on the non load side or load side or both?
  13. B

    Underfloor heating RCD tripping

    Hi. Before I call an expert out any thoughts on why my RCD has suddenly started tripping even when the power to the UFH on the thermostat is turned OFF? But trips sometime with heating on? If it's tripping with power off, could it be the thermostat, or a broken thermostat? The flooring has...
  14. B

    Optima G3 Alarm Beeps twice Every 5 mins

    Well, Ive sorted this after getting the Engineers manual.'Flag B' options: "Line fail Active high" was set.I deselected it and beeping gone! Voila! Hope this helps someone else.Thanks for the replies!
  15. B

    Optima G3 Alarm Beeps twice Every 5 mins

    Nope, definately not this. I enabled the chimes OK but have disabled them again.It`s every 5mins, 2 beeps.Anyone?
  16. B

    Optima G3 Alarm Beeps twice Every 5 mins

    No. It`s definately coming from the alarm panel and it`s never been (not even sure if it`s capable of) being attached to a smoke alarm so it`s not that.Thanks for the suggestion BTW
  17. B

    Optima G3 Alarm Beeps twice Every 5 mins

    Hi.Ever since my little daughter had her mits on the alarm control panel (Optima G3), the internal beeper beeps twice every 5 mins!! I`ve tried reseting and printing off the manual for it but I can`t silence it.It`s driving me nuts.There was mention that the beeping was down to the fact that it...