Search results

  1. F

    Flow restrictor position WB 28i Junoir

    As above could anyone tell me where the flow restrictor is situated on said boiler please. My dads hot water flow has reduced recently, I've checked the filter near the flow switch but thats clear and I want to check the flow restrictor for blockages. TIA Filsyn
  2. F

    Ideal Boiler not Working..Please Help :(

    Your boiler has overheated due to air in the boiler, turn all rads off except the closest to boiler. I don't know how competent you are but when I have this problem I usually take the diverter head off and manually push the valve spindle in letting the water move through the ch flow whilst...
  3. F

    Gloworm 30cxi combi boiler has died

    Get an engineer in as it sounds like the PCB, and on these I'm pretty sure you'll need both the main PCB and the user interface PCB.
  4. F

    combi 80 not sensing flame on CH

    It's probably going to lock because when the DHW modulates to low flame it isn't sensing the low flame. If you're not gas safe registered call someone in who is and explain this may be the fault, if this is the fault (and thats what seems to be happening) then it will only take him a short time...
  5. F

    combi 80 not sensing flame on CH

    You may need to adjust the flame rectification probe, it works OK on DHW because it goes straight into full burner and when there is a demand for CH it isn't sensing it in low burner, I've had this once before.
  6. F

    Turbomax plus 828e DHW fault..

    I have a problem with the above boiler on the hot water side, when you call for DHW the boiler fires up OK in low burner but then stays in low burner with the temperature lingering at about 55 degrees c (control set to high). After maybe 2-4 minutes (period of time varies) the burner comes on...
  7. F

    replacement for keston celsius 25.

    The boiler Will be getting moved to an outside wall so flue length isn't an issue.
  8. F

    replacement for keston celsius 25.

    I'm looking to replace one of these boilers and was wonder what a good replacement would be as I've been away from the tools for a while. Its being connected to a heatrae sandia unvented cylinder.
  9. F

    3 port divertor hot case

    With the hot water only only on check the white wire in the 10 way for 240v using a multimeter, if no 240v then the body of the valve is passing, if there is 240v then disconnect white wire and check white wire for 240v if you have this on the wire on it's own the actuator head is faulty, if the...
  10. F

    BAXI 105HE

    Have a look on top theirs probably a co detector or smoke alarm. :wink:
  11. F

    New Boiler? - Powerflushe? - Keep Old? - What to do????

    Option 4, put some X800 in for a few hours then drain the system, removing and flushing out each radiator 1 at a time and then refill and drain a couple more times, this could sort you out for a few years. It all depends on how you are financially, option 2 is just throwing money away IMO, if...
  12. F

    New programmer but no hot water

    When you swapped the wires over did you go "heating on" to "heating on" etc, or did you swap them "1" for "1", "2" for "2" etc? Also you seem to have a permanent live to HW off via link?
  13. F

    New programmer but no hot water

    What was the previous programmer fitted?
  14. F

    Boiler gas light turns on

    For £500 you won't get a Worcester, and if you thinking £500 for boiler and fitted you've no chance, you'd be lucky if you get a single point water heater fitted for that.
  15. F

    isar/ icos heat exchangers

    The scrap value from one of these is worth more than the boiler ever was... :shock:
  16. F

    sime friendly format 80e hot water problem?

    It's not the diverter valve, that's operating correctly and not passing through to the CH, I'm a heating engineer but unfamiliar with sime boilers and wanted to know if this is a known on this particular make and model, I've tested the thirmistor and that's OK as far as I can tell without having...
  17. F

    sime friendly format 80e hot water problem?

    As above the boiler fires up OK in hot water mode (central heating works fine) but seems to reach temperature too quick within the boiler although it never gets better that warm at the tap. I've not worked on these boilers before and I've come the conclusion that the water to water heat ex is...