  1. R

    Honeywell Evohome experts advise sought

    hello Dan, sorry but I understood that you could not answer all of my questions but now you have answered them albeit in a different thread ! my personal preference would be for option 1 because its cheaper, does not require mains and I feel i could do it myself. The only issue is the depth of...
  2. R

    Underfloor heating control

    ok thanks, i opened a specific evohome thread perhaps someone will latch onto the keywords.
  3. R

    Honeywell Evohome experts advise sought

    hi, i am seeking advice on the configuration of the wireless evohome system to an existing UFH installation.What i need to know is how precisely could i configure such a system and which individual components would be required. I raised a general thread and in this my requirements and current...
  4. R

    Underfloor heating control

    sorry cut and paste error http://www.gruenspar.de/honeywell-evohome-gateway-starter-paket-pro.html what this kit does not mention is how the zones to be controlled report their actual current temp to the control panel, presumably one needs something like this...
  5. R

    Underfloor heating control

    http://www.gruenspar.de/honeywell-evohome-gateway-starter-paket-pro.h
  6. R

    Underfloor heating control

    what perhaps you cannot appreciate is that the cabinet housing the controls is set in a precast concrete wall so whatever there is available has to fit in that space envelope. the valve threads are 30x1.5 the spec of the HR92 states also 30x1.5, you wrote that HR92 are a mixture of mains and...
  7. R

    Underfloor heating control

    10/10 for observation ! yes you are correct the property is not in the UK. i had a quick look at Honeywell evohome, that looks to be exactly what i need, if no suitable actuators are available is it not unreasonable to swap the manifold out for one which supports a suitable actuator ? From the...
  8. R

    Underfloor heating control

    Hi, what exactly do you wish to see pictured ? The only thing i could imagine being useful is this
  9. R

    Underfloor heating control

    I live in an apartment block where the boiler, cylinder, main controls are located in the cellar. The rooms are primarily heated by underfloor (tiled) heating elements. The seven heating zones are controlled within the apartment from a valve bank, a main on off and then a hand adjustable valve...
  10. R

    re-roof commments please

    hi, the loft space has been ripped out and replaced with load bearing joists and boarded out with services. The rafters are good,The purlins are in very good condition no bowing or rot and the wall pockets have been redone so that the purlins sit on engineering bricks or in the case of the...
  11. R

    re-roof commments please

    Hello Dave, first I must confess that I am not in Blackpool I put that up because I am living overseas and do not wish to attract attention. Did you look at the photos in my gallery ? Is it possible to estimate the condition based on those and my concerns ? I think the broken ridge in itself is...
  12. R

    re-roof commments please

    did you have anything in particular in mind when you mention worms ? I was thinking that if the entire roof is rebuilt, with new ridge, all new leadwork,repointed stack, new gutters, new slates where necessary, felt, battens then there could not be any worms. My main issue is why this...
  13. R

    re-roof commments please

    calling all roofers, i would really appreciate your comments about my roof. The ridge piece has broken at least 20 years ago see sag The tall stack on the front view is mine and is not shared, in my opinion the lead is shot and needs completely replacing. The front view shows the join to...
  14. Untitled

    Untitled

  15. Untitled

    Untitled

  16. Untitled

    Untitled

  17. Untitled

    Untitled

  18. roof

    roof