  1. G

    Room Thermostat not turning off central heating.

    Thanks for that. I did wonder because the system/ symptoms are not the same. I don't want to replace bits unnecessarily And ... is it easy DIY job? I see direct replacements advertised with same wire colours etc
  2. G

    Room Thermostat not turning off central heating.

    May I revive this thread and ask about a similar scenario: Our system is less than 2 yrs old. Oil boiler and pumped system with three circuits - two-zoneUFH/rads/DHW - each with two-way Honeywell MVs After the programmer reaches its "OFF" time, the room stat still shows red light and the...
  3. G

    Gravity flap wall vent

    I need two of these to tidy up where my cooker extract ducts come through the outside wall At least 200mm square and preferably black or grey Flush fitting though maybe I could cut off any flange Can someone point me in the right direction please?
  4. G

    Engineered Oak Floor over anhydrite screed/UFH

    From the Elastilon website - "Elastilon Strong can be used on under-floor heating in combination with solid wood or constructions." The Lock version does not sound like a diy job! But I'm sure you're right about the DPM - half my project already has UFH + anhydrite screed and that was poured...
  5. G

    Engineered Oak Floor over anhydrite screed/UFH

    I want some real-world BTDT advice. The room planned is about 11mx6m with anhydrite screed and wet UFH I think I want wide-board engineered oak Questions: Mostly I've read that screed moisture content needs to be <0.5%CM Carbide method does not sound like diy task - who do I get to measure...
  6. G

    How to replace butterfly tube

    Thanks to all. Job done
  7. G

    How to replace butterfly tube

    As per title .. can someone please explain One of my outdoor lights (Lombard) - under the soffit -started flickering Took off the cover/diffuser but can't see how to replace the "butterfly" tube - it's GE polylux F282D/835 The plastic fitting is very flimsy and I don't want to force and...
  8. G

    Fitting room thermostat

    The attic/loft/garret whatever was previously converted to extra bedroom space. It has very limited headroom, little spaces to squeeze past chimneys etc and no natural light It will be impossible to take wide pictures showing large segments of the layout The pipework is mostly covered in...
  9. G

    Fitting room thermostat

    Thanks D_H Eventually found it The attic is a maze of pipes and wires It says on the box -Honeywell Sundial Y Plan V4073A1039
  10. G

    Fitting room thermostat

    Thanks guys I think I'm out of my depth already But maybe I can learn enough to have a sensible conversation with an electrician! How would I tell if I had Y or S-plan The loft is full of pipework and I've had a quick look around Is this where a frost thermostat would be? There is nothing...
  11. G

    Fitting room thermostat

    Hi folks Just joined & my first post. My gas CH = GlowWorm Hideaway + ACL LP241 programmer All rooms have TRVs but there is no room thermostat. I want to have frost protection when away for a few weeks in the winter What is the easiest/cheapest way to do this? I'm thinking about a wireless...