Search results

  1. M

    potterton statesman 50/70 oil boiler problem

    again thanks for your responses,slapper,oilhead,agile etc.as i am at a loss at moment,i take all that you have said on board.i must admit i did not clean boiler on second visit,the nozzle i replaced was .60 60 deg ES which is as original. i need to get back to boiler and start from scratch i...
  2. M

    potterton statesman 50/70 oil boiler problem

    thanks for all replies,the boiler was installed by heating company approx 3 yrs ago but were not prepared to service it when customer asked. i was asked(oftec reg) to look at boiler when problem arose.i cleaned all baffles and heat exchanger it was really sooted up,i found that the heat...
  3. M

    potterton statesman 50/70 oil boiler problem

    have 3yr old statesman 50/70 boiler,it is smoking v.badly(black),boiler serviced and new nozzle fitted,also new pump assembly,pump pressure reset,oil lines and filter cleaned and bled.boiler fires up ok but is running v.rich,no amount of adjustment of air damper seems to help for long.flue gas...