Search results

  1. J

    eden vbx 30 flame failure.

    Hi. It failed to ignite over night so I set the gap to 3.5 mm from 2mm that it was and it been working fine since. thanks for the info.
  2. J

    eden vbx 30 flame failure.

    yes your right. we not been in this house long. I've got it to work. I took the igniter and the flame sensor out and they had light brown soot on them. I cleaned them and its fired up. I'm just heating the house and water up then I'm going to clean it out. It looks like it needs one looking...
  3. J

    eden vbx 30 flame failure.

    Hi all, our boiler been working fine then i came home yesterday and it had gone out. it would. nt lite until i turned the fire out upstairs then it lit until the middle of the night some time then went out and wont light again with error code 3. Flame failure. I dont think the gas pressure has...