Search results

  1. H

    Fitting Oak strip to joists.

    I'm back on fixing again. What nails will drive through oak or should I drill a small pilot hole first?
  2. H

    Fitting Oak strip to joists.

    I thought fibre wool would have a draft flowing through it as under floor there is always a draft (I can fell it when I go down there) so not so effective as a solid insulation like foam. Also, surely it should be a push fit between the joists to seal the edges. I think given that I have to put...
  3. H

    Fitting Oak strip to joists.

    OK, thanks I will make an acces hatch to get at the pipes etc underneath. Anyone advise on insulation and vapour barrier?
  4. H

    Fitting Oak strip to joists.

    Then how do you get the floor up one day without destroying it?
  5. H

    Fitting Oak strip to joists.

    How are the lengths fixed. Is it a special sort of nail or do I srew them down from above?
  6. H

    Fitting Oak strip to joists.

    Thanks. I think I will lower the existing chipboard to between the joists giving an all over support. I also want to insulate under the lowered parts with I suggest polystyrene allowing air to circulate around the exsposed joist parts. Any suggestions for an extra air barrier under the oak...
  7. H

    Fitting Oak strip to joists.

    I have aquired 9m2 of 90w x 18mm strips (1.2, 0.6 & 0.4m long) of solid oak flooring and want to know how to lay it. I have a kitchen floor which I will remove the 18mm chipboard (there is no option to lay over). The joists are 50mm wide and about 450mm apart. I guess there must be some sort of...
  8. H

    Garage with some electrics in place

    No. I shall research the job untill I've got it right then proceed within the rules. Thanks for your time. If I need to post again I will return.
  9. H

    Garage with some electrics in place

    Thanks all. OK, so as we are single phase I seem to have the option of tying black to earth (sleeved Y/G) and black to earth or neutral (sleeved appropriatly). I see the appropriate glands are these but not utilised - don't ask me who fitted it, I don't know. Yes there is an 16A MCB...
  10. H

    Garage with some electrics in place

    Cores for earth? Yes as I see that the sheath although will be clamped and earthed both ends, it may not be enough resistance to act as a fault earth under certain conditions so I will use one for earth and tie it to the sheath/earth bar. Is it usual to tie the earth wire of the cable to the...
  11. H

    Garage with some electrics in place

    I have a garage with a CU with RCB (30Ma) lights and power circuits. It has an armoured cable going to the house CU to a 16A breaker on the MCB side. I think I should get this end connected to an RCBO of 16A and 100ma. Is that right? PS I know that if a Freezer is connected in the garage...
  12. H

    Secret space.

    I have a "slot" in the side of my fireplace (breast) which is floor2ceiling and abot 100mm wide, 200mm deep so quite narrow. I am trying to think of a way of making a set of cubbyholes which are concealed so I can put treasures etc. Something say like small draws with push release catches. It's...
  13. H

    Check Valves.

    I assume that if the mains tap is OFF then it won't allow flow in either direction. Also isn't is a battle against pressure? Our mains is of very high pressure compared with our gravity system. Interesting that a tap can pass when the taps are OFF. Of course the tap is to supply water to the...
  14. H

    New bathroom questions.

    Interesting echoes, thanks.
  15. H

    New bathroom questions.

    Thanks, your comments lead me to the conclusion that the bathroom basin (separate taps) will be mains and bath taps/shower, mixer and toilet will be tank. I will leave the cloakroom as hot/mains but will check the model of mixer tap and fit a stop in the hot supply if necessary.
  16. H

    Check Valves.

    Thanks, thought - if hot into mains only occurs when the mains tap is OFF then I don't see a problem except that any mains tap turned on in this state may receive hot water if the responsible mixer tap is also turned on! Hot water certainly won't go into the mains supply pipe!
  17. H

    Check Valves.

    I have just reviewed this issue for my plumbing and realise that I do not have anything installed (check or stop valves) on my cloakroom mixer tap from B&Q. There is mains on cold and tank on hot. Should I need to fit something here?
  18. H

    New bathroom questions.

    I am fitting a new bathroom and would like advice on: 1. The mixer shower requires even pressure inputs so do I need 2 x 22mm hot and cold or would 22mm hot and 15mm cold (from loft tank) do? 3. Currently all cold is mains. Which taps should have cold from tank? 4. The basin has a combo...
  19. H

    Another Cold Water Tank Question - Slightly different.

    Thanks, TicklyT I think that's the basis for a solution. We probably only need about a couple of sq. foot of bare ceiling to do that.
  20. H

    Another Cold Water Tank Question - Slightly different.

    I have, the tank comes with such a kit. My particular problem is not related specifically to bylaws.
Back