Search results

  1. M

    motorised valve problem

    hello not getting much help here... could I have wired the grey wire to the wrong terminal??
  2. M

    motorised valve problem

    I initially changed the body which was a landis & gyr mav 322 for a siemens cav something.. anyway it is compatable. I only took the actuator off the siemens to see if i could move the spindle...the thing is I still have exactly the same problem as when I had the L&G.. the electrics appear to be...
  3. M

    motorised valve problem

    this is a new valve & I've got exactly same problem as I had before I changed it
  4. M

    motorised valve problem

    have done a bit more testing here turned off fused spur to reset no calling 230v grey 77v orange HW 230v orange 230v white... lever resistant CH 230v white 230v grey... lever floppy HW/CH 230v white 230v orange... lever floppy Took the actuator off & tried to move the valve...
  5. M

    motorised valve problem

    Ok got the MMT back... Have tested the white wire with heating & water on & heating only, power fine... Tried moving the manual switch it wont budge!! Also the boiler is only firing up for a couple of minutes then off then back on 2 minutes later... As the manual switch won't move wondering if...
  6. M

    motorised valve problem

    Hi, I have an old baxi solo 2 boiler. During the summer I noticed hot water heating the rads so I turned them off. When it started getting colder I turned the heating on but it wouldn't work without the hot water on. The rads were hot but couldn't adjust the temp. Like an idiot I thought it...
  7. M

    baxi solo2 fan burning out

    OK thanks... the most helpful reply of all
  8. M

    baxi solo2 fan burning out

    I replaced both gaskets the last time I changed it plus I have a carbon monoxide detector I bought from Amazon for £20... what you people don't seem to understand is that not everyone can afford to call out a repairman... for a new fan & someone to install it would have cost me over £200
  9. M

    baxi solo2 fan burning out

    well thanks for all your replies... firstly the first fan I fitted was because my CH broke down on Xmas eve .. everywhere was closed or doing inventory but I was lucky to find a plumber who had an old boiler & sold me its fan... which I fitted myself as there was no one else... hey this is not...
  10. M

    baxi solo2 fan burning out

    answer to the 1st post .. I don't know maybe 10yrs 2nd post ..It was a recon fan from all spares direct .. It was them that told me that it wasn't a problem with the fan & refused to replace it under the 1 yr warranty... I fitted it myself the third one since new ... Yes the gaskets were OK ...
  11. M

    baxi solo2 fan burning out

    Hi I've got the above fan & tried to replace it under warranty only to be told that my boiler is overheating & that was the reason it burnt out....consequently the warranty was no good...I don't really understand how the boiler can overheat & what if anything can I do about it
  12. M

    hoover washer door lock

    checked continuity on lock & wires....have continuity between 3 & 2 but none between 1 & 3 on lock.. continuity both OK on wires...ordered a new lock & fitted it but no joy... didn't test it before installation but tested it after...seems the same as the old one no continuity between 1 & 3... am...
  13. M

    2 rads working heating not on

    Ok I guess you mean the switch that cuts off the heating & directs it to the water... But it's still strange though, one rad is quite close but the other one is far away in the bathroom.. Anyway thanks for the info will check it out
  14. M

    2 rads working heating not on

    just started far as I can tell... Baxi solo 2..just changed the fan a couple of days ago with an old one I had that's very noisy, the other one had packed up...can't think that has got anything to with it though
  15. M

    2 rads working heating not on

    hi got a strange problem.. although my CH is switched off i'm getting two rads warming up when the hot water supply comes on... how can that happen?
  16. M

    hoover nextra no power

    can the bushes burning out cause the problem... my wife said she smelt something burning
  17. M

    hoover nextra no power

    checked continuity on lock & wires middle green cable OK.. middle & white cable nothing.. suppressor OK selector switch OK no visible damage on control panel or PCB
Back