Search results

  1. D

    Potterton Performa 24 not igniting

    Thanks to Agile for help. Turns out the venturi in the flue was distorted through heat, thus not allowing pressure differential to activate air switch. Engineer hadn't seen this before.
  2. D

    Potterton Performa 24 not igniting

    Tony, Thank you for your help so far. If you consent to advice over the phone, please let me know when is convenient for you (think you can pm me if you accept friend request, or reply). If not, I understand why and no hard feeling. Daniel.
  3. D

    Potterton Performa 24 not igniting

    OK, thanks for that. Held against reset for 1 minute but no change to symptoms.
  4. D

    Potterton Performa 24 not igniting

    Yes, reset by holding selector knob against spring pressure for >2 seconds. Thanks for the suggestion.
  5. D

    Potterton Performa 24 not igniting

    Thanks very much for reply. Yes there is continuity across this switch.
  6. D

    Potterton Performa 24 not igniting

    Hi My performa 24 combi refuses to fire up when CH/DHW is demanded. I have been through the fault finding in the manual but it hasn't helped- DHW for example: pressure switch operates diaphragm OK microswitch provides 230V pump runs fan runs air pressure switch provides 230V ignitor...