Search results

  1. D

    New outbuilding. Cavity wall or single skin with V barriers?

    Thank you for your reply... can i ask what you mean by fill insulation is this the same or similar to when companies advertise cavity wall insulation.... drill holes and fill with what i can only amateur explain as expanding foam :lol: My biggest concern is damp. I've had a string of...
  2. D

    New outbuilding. Cavity wall or single skin with V barriers?

    Hi all.... first off thank you for taking the time to read this :D I want an outbuilding in the bottom of the garden. I have spoken to the planning department who just refer me to the limitations based on their funky little guide and have spoken to a helpful chap at my local building...
  3. D

    Condensation forming puddles on bitument in extention

    The main reason for not insulating the walls is that room is less then 2 metres wide, with the battons and plasterboard obviously now even thinner obviously. With the plasterboard off the ground thus a gap between the floor and wall would this still not be happening even with the insulation...
  4. D

    Condensation forming puddles on bitument in extention

    Hi all. I'm in desperate need of advice please and want to thank anyone that can advise anything in advance! I have single brick (what used to be) a porch and storage room at the back of the house. It used to get damp in the at the back bottom right and left corners... I wanted to make the...
  5. D

    Want to laminate the floor with tiles on the walls...

    Hi, at the moment I have bare floor ready for laminate to go down and plaster board walls. The plasterboard is secured to batons not dot/dabbed. I need to be able to wipe down and clean the walls and floors as it'll be used for tattooing hence why I want to go with tiles on the walls and...
  6. D

    Adding an extra radiator in the extension....

    The Boiler is a Proforma 28 and the copper piping is 15mm As I put in my first post most of the work will be done. All the plumber would need to do is soldier the joints which there would be a max of 10 joints. £250 for 10 joints and fill the system to check for no leaks? I think not...
  7. D

    Adding an extra radiator in the extension....

    Hi folks! I have a combi central heating system and need to put a radiator in the extension. I have no problem putting the radiator up, draining the system but when it comes to doing the pipe work I feel I maybe a little stuck. The 2 radiators (new and the feed rad) will be on the same...
  8. D

    Insulating a single wall out building - Valid questions.

    Hi there folks :D Firstly this is going to be a big post I know it so will start by saying thank you to anyone who reads it entirely and a further thank you to anyone that can help, suggest options or suggest alternatives. I found this site while looking for advice on insulating our...
Back
Top