  1. G

    Y plan electrical fault

    You should have got a heating engineer not a plumber, who could have done the wiring as well. The valve is normally cold when not in use, but that will depend on how long since the system was last fired up, could take hours. The pipe to the pump and after the pump would normally be hot if...
  2. G

    to drain or not to drain,that my friends is the question

    Then how did you fit it to the system.?
  3. G

    Back Boiler Pilot Light Keeps Going Out - Service or Repair?

    The thermecouple needs replacing, have the boiler serviced by a local engineer, needs some TLC. Will not cost a great amount.
  4. G

    SIME SUPER 90

    Sent.
  5. G

    SIME SUPER 90

    If you supply an email in your profile and you are an RGI, I will send you one, if your inbox will accept it. Otherwise you can get one here http://www.a2zboilermanuals.co.uk
  6. G

    Radiators Hot but no hot water

    You have an airlock in the hot water circuit.
  7. G

    Kitchen cupboards either side of a cooker

    Worst case secanario.... Gas 50mm from either side min 760 directly above unless manufacturers instructions specify different.
  8. G

    vaillant turbomax 242E manual

    You can download manuals from Here.
  9. G

    Looking for a corgi book

    Find the better one here: http://www.vipergas.co.uk/index.asp
  10. G

    WORCESTER 42CDI

    No, it will not cause any harm.
  11. G

    Fitting toilet after raising floor

    Yes, one of these, an ofset pan connecter. http://www.screwfix.com/sfd/i/cat/02/p1062302_l.jpg
  12. G

    Bath Installation Sequence

    What you think Agile is irrelevant, as it is plainly obvious you have not a clue about fitting a bathroom professionally.
  13. G

    System for extension

    Twenty litres per minute flow for the unvented, the combi should not reduce the mains pressure, may need to have a new mains supply or at leasted checked by water board.
  14. G

    System for extension

    Add an unvented cylinder for your hot water needs, have the combi just feeding the kitchen taps, the extra rads will not be a problem for the boiler you have.
  15. G

    Secondary return

    Its more a case of if you want the system or not, the pumps are generally timed for the periods of bathing or hot water usage, the system can include towel rails and the pumps are temperature controlled as well as timed.
  16. G

    Main Combi 24 HE no pressure how do I replace it?

    Turning the water off and on will not affect the system pressure, bleeding radiators will lower pressure as will a leak on either your system or your boiler.
  17. G

    Quick quote

    Its your choice really, if you can find a muppet to do it that way. Save yourself some more and just do it yourself.
  18. G

    Vokera 20/80 RS Flowmate

    Look for the filling loop, normally silver braid pipe, with a lever or screwdriver slot at one end, top up pressure to 1.2 bar.
  19. G

    New boiler advice

    BG will also give you a loyalty bonus of £150 and pay you £150 for your old boiler and you will still pay a £1000.00 more than the norm.
  20. G

    LEAD LOCK FITTING

    No, he did'nt you did. 6/7lb 1/2inch, 9lb 3/4.