Search results

  1. J

    Ideal Mini C24 lack of burner ignition

    The repairs are not illegal. I'm competent and not charging, therefore not illegal. I very highly doubt the landlord has any insurance. What would it matter if I am in receipt of benefits or not. Anyway, the boiler is back together in it's state of not firing and staying that way for the...
  2. J

    Ideal Mini C24 lack of burner ignition

    The relays are fully functional, as stated in the first post. I've just been in contact with a boiler replacement scheme so as long as I can get in contact with my landlord I'll have a new boiler soon. I aren't getting my hopes up though -_-
  3. J

    Ideal Mini C24 lack of burner ignition

    Ok, that's fine. Hopefully I'll be able to find someone to do a cheap diagnosis in my area. The heat exchanger was removed ages ago now and I highly doubt that has anything to do with the issue. This literally only started happening a week or so ago. Thinking about it the boiler was serviced...
  4. J

    Ideal Mini C24 lack of burner ignition

    Hi, looking for a bit of advice on a repair. My ignition PCB is faulty. Ignition relay isn't getting any power so boiler fails to ignite. I have removed and tested the relays which power at 16v externally, the boiler gives 1 relay 29.5v, the other around 0.6v. Any thoughts on how to repair? I...
  5. J

    Ideal mini C24 DHW issues.

    Hi, Pete here. Had an issue for a while with our boiler (Ideal mini HE C24). DHW never fires, we have to turn on the heating, make sure boiler is lit and then turn on the tap. When we try without the heating on first, the boiler pumps fine, but the green light continually flashes at a fast...
Back