Search results

  1. W

    Moving a consumer unit

    Just to add there is already a cut out switch by the main fuse
  2. W

    Moving a consumer unit

    Thanks for the replies. The switch's are plastic back box's are metal. The tails will be cut shorter because it will be closer to the main fuse. I literally want to move it 4 inch's
  3. W

    Moving a consumer unit

    I need to move a consumer unit onto the opposite side of a wall where it is currently situated. The circuit wiring will all be cut shorter so no extensions to the circuits will need to be added. The consumer unit is a plastic one in good condition. The lighting circuit is earthed but not to the...
  4. W

    Roof issues with marley modern smooth interlocking tiles

    Hi. I'm currently doing a small pitched roof with a roof window. The tiles are marley modern smooth and the roof window is a sunlux with a universal flashing kit. It abuts to a wall where I have used a grp secret gutter. Firstly the flashing kit is causing me a head ache because it is causing...
  5. W

    RCD test fault

    Yea. oh well ive got new leads on order!!
  6. W

    RCD test fault

    I had the tester calibrated at a different place last year and they told me i needed new leads which are now the faulty ones. So they must have tested my leads then
  7. W

    RCD test fault

    There isnt a fuse. I did suspect these leads were faulty a few weeks back i had a few dodgy readings on an insulation test but when it came back from the calibration with everything ok I obviously thought they were ok.
  8. W

    RCD test fault

    I believe i may have found the issue. I changed my test leads for another pair and it wasnt working just i got the 1999ms reading yet 2 minutes ago with the different leads it tripped fine.
  9. W

    RCD test fault

    Ive just done a x5 test on another house im at with the same tester and it was perfect 12ms ?
  10. W

    RCD test fault

    my meter was only calibrated and tested last week so i would hope itl is in working order
  11. W

    RCD test fault

    Yea sorry it just read 1999 which i just presume to be ohms because thats the reading i get when i do my insulation resistance tests. I had a faulty rcd before that didnt trip and it came up with an error exceeding 500ms maximum limit. so thats why i wasnt sure with this error
  12. W

    RCD test fault

    Ive got a zs on a 6mm cooker radial circuit of 0.27 Immersion heater circuit with 2.5mm radial of 0.15 2.5mm ring circuit of 0.40 Im using a telarus unitest 0100 multi function tester
  13. W

    RCD test fault

    Its a PME with a ZE of 0.07ohms
  14. W

    RCD test fault

    they were still connected but I turned the mcb's off
  15. W

    RCD test fault

    Hi I was testing 2 new rcd's yesterday on a split consumer unit. They are bs-en type the first one tripped in 23ms and the 2nd tripped within 25ms but when i tested x5 i was receiving 1999ohm error? I tested them at the consumer unit and still got the same error. The test buttons...
  16. W

    vat!!!

    see this is how i calculate it. my current situation my profit £30,000 my materials costs are around £10,000 subby costs around £27,000 other costs £8000 Total £75,000 I know I could do commercial work but its not what i want to do. I would like to take probably 1 or 2 more...
  17. W

    vat!!!

    Hi thanks for the replies. Yea my current profit is around 30k my subbies are not vat registered.
  18. W

    vat!!!

    Hi I'm looking for some feedback and advice. I'm a small business dealing with private domestic home owners providing home improvement work. There is myself and a couple of subby that I use. I am flat out until August with work. I want to expand the business and take on a few more...
  19. W

    Compression adjustment on a 3d flag hinge for upvc back door

    Hi we fitted a upvc door last summer, we went round today to adjust the door because it wasnt locking properly. When we arrived there was a gap between the frame and door at the top on the lock side of aprox 5mm. This wasnt like this when we fitted it and the door locked fine. Because...
  20. W

    Results on a continuity test on a final ring circuit

    I think thats solved my issue with the higher reading on the cpc thanks guys