Search results

  1. D

    Toad AI606 help

    if you could let me have the info that would be helpfull battery is ok but needs changing soon ...many thanks for your reply
  2. D

    Toad AI606 help

    I all I have a Toad ai606 alarm fitted to my car and I want to disconnect the battery ..will this have any affect to the alarm system as ive heard that you have to set the alarm to service mode ?? don’t know how you do that ??? help
  3. D

    Electronic control potterton prima 30 HELP!!!!!!!!!

    Hi all I need a PCB for my potterton prima 30 boiler part number 407677 Where’s the best place to get them from, as I know that they are very expensive I need one urgently any ideas any one got one in their shed ?????? Kind regards
  4. D

    potterton prima 30 fault

    Hi all got a potterton prima 30 boiler, had a few probs last year with the gas valve clicking on and off this turned out to be a loose joint on the circuit board. Didn’t find this out until I had the gas valve changed and it still did the same thing. Any way now its developed a new problem...
  5. D

    shower pumps

    Hi all does anyone know if there are inline shower booster pumps that I can fit ot my mixer shower that are suitable for loft installations
  6. D

    fitting a pump to a shower help!!!!!!

    all the pipe work is as spec per the instructions but i would like to fit the pump in the roof and not have to alter the pipe work that i have now ,,the manual says that if i fit in the roof it may suffer from airlocks but i used to have a single impeller pumped power shower and that worked...
  7. D

    fitting a pump to a shower help!!!!!!

    Hi all I have a mixer shower gravity feed hot and cold which the pressure is not bad on but I want to boost it so Ive got a twin pump I want to fit in the roof and not in the airing cupboard If I just divert the hot and cold in and out the pump and fit it in the roof will this work ok or...
  8. D

    new shower ideas???

    Hi, all I have gravity feed cw & hw power shower 240vac pump integrated system at the moment and I ‘m refitting my bathroom and need a new system as this is so noisy. Ive seen a hydro shower @ wickes which I think means that it has a mains cw and a gravity feed HW supply. My question is will...
  9. D

    help im baffled

    tt over head system.............
  10. D

    appliance-switched fan

    You can get fans of 4inch dia that have a humidity sensor incorporated in them but I don’t know if when the machines started this would work??? You could use a thermostat on the dryer to trigger but not sure about the washer maybe a proximity probe
  11. D

    Where am I going wrong with my loft light?

    dont forget part P of the regs you shouldnt be doing home diy electrics anyway :shock:
  12. D

    help im baffled

    why have you got the hob and oven on an rcd ?? do you have a split dis board or is your electrical supply via overhead cable because as a rule you never but them on a rcd because when an element is cold it can get damp and the moisture in side causes the rcd 2 trip,sounds like the oven is faulty...
  13. D

    Where am I going wrong with my loft light?

    hi m8 what you have done is youve connected into the wrong cable although its a red and black its sounds like you have connected to the switch wire and feed to your light switch ,,on new installation we use twin red to the switchs ..well now its brown brown you need to find a perment live and...
  14. D

    potterton prima 30f

    think ive found the fault its was a dry joint on the pcb the perment live to the air flow switch ive resoildered it and touch wood its working ok for now ...thanks for your help Regards
  15. D

    potterton prima 30f

    just checked that mate and the joint is fine no lose connections any other ideas ...if the boiler is cold it will start clicking in about 1hour when switched on its the increase in voltage i dont understand and ive been a spark for 14 years ,,, ive had 2 meters on it and they both read when i...
  16. D

    potterton prima 30f

    i had a plumber fit the valve iam a electrician ..... the valve has 2 solenoids gv1 is the poilet burner and gv2 is the main burner this is what keeps clicking like it is loseing its supply but it is not the voltage goes up could it be be pcb ????? @ fault
  17. D

    potterton prima 30f

    Hi I have a potterton prima 30f I have fault on the gas valves they keep clicking loudly so I changed the valve and the problem is still there I have tested the voltage to the valves and when it starts clicking the volts rise from 240v to 400v is this a fault on the pcd side????? Regards
Back