  1. S

    glow worm protherm 60/80 ci

    Yes we carried out the fault finding checks to the manufacturers instructions!!!!! I cant see how the fault has got worse, maybe its a faulty board!! Just thought you guys could shed some light on the problem. thanks anyway.
  2. S

    glow worm protherm 60/80 ci

    Intermittent voltage to the fan (hunting) so spoke to technical help and they said replace board so we have fitted new board today but the problem is now worse no power at all to the fan :mrgreen: . Any help will be greatfull. thanks Steve
  3. S

    electro oil stirling 40 burner problem NAILED

    With reference to my recent post regarding this problem I would just like to say Thanks for your help Especially Boilerman2. IT WAS THE ACCESS DOOR SEAL causing recycling of the flue gasses! I didnt actually check this as the previously so called competant company who carried out the last...
  4. S

    electro oil stirling 40 burner problem

    Got the same problem again the customer rang to say its still intermittently locking out AGAIN. Started on friday, it will run for a few minutes or hours!!! so today i will order a new motor capacitor as everything else has been replaced apart from the motor and oil pump. Any further...
  5. S

    electro oil stirling 40 burner problem

    Well thanks again for your help I managed to get the outlet valve from the tank to close and removed the filter found to be virtually blocked with deposits also removed and cleaned the oil pump filter and just as bad. this boiler was supposed to have been fully serviced 6 months ago!! I...
  6. S

    electro oil stirling 40 burner problem

    great thanks once again for that will check and clean today.
  7. S

    electro oil stirling 40 burner problem

    As the motor capacitor has been mentioned a couple of times I am wandering if it fails to start the motor intermittently maybe after a week or so and this is when lockout occurs!!
  8. S

    electro oil stirling 40 burner problem

    Hi again Unfortunately there is no filter on this particular danfoss oil pump! thats a first. I have checked the rope seals and all ok also carried out another combution check burning nice and clean not sure about what the CO2 should be but set at 10.9%. C how long it runs for this time!
  9. S

    electro oil stirling 40 burner problem

    Havnt cleaned the oil pump filter yet but will do that tomorrow. Thanks once again
  10. S

    electro oil stirling 40 burner problem

    OK Boilerman 2 thats the next first thing I will do on monday. will let you know. Steve
  11. S

    electro oil stirling 40 burner problem

    Thanks once again to you guys I will replace the motor capacitor on Monday. Btw I have already replaced the solenoid and also think I mentioned previously there were sticky deposits on the sides of the nozzle after just a week! steve
  12. S

    electro oil stirling 40 burner problem

    Ok thanks again for your help will check that rope seal and see if that fixes the problem.
  13. S

    electro oil stirling 40 burner problem

    Thanks for that. You are correct re no air tube connected to burner and the tank is slightly higher than boiler. Forgot to say when I changed the nozzle just a week ago the existing nozzle was only fitted two weeks prior to that and noticed the inbuilt filter was slightly discoloured! I...
  14. S

    electro oil stirling 40 burner problem

    This burner is fitted to trianco eurostar wm 50 in the wall boiler Serviced a month ago and keeps locking out at the control box, the boiler will run for a few days then lock out at any time in the day.It will restart after pressing the reset button. carried out another combustion test today...
  15. S

    GLOW WORM SWIFTFLOW 100 COMBI

    thanks for that but whats the cc? steve
  16. S

    GLOW WORM SWIFTFLOW 100 COMBI

    Thanks for that tony. I am a gas safe engineer just need some help on this one, I have carried out several repairs to this boiler so far but this recent fault is a pain. BTW the pilot stays lit , its as if there is an interuption to the gas valve of electricity!! Steve
  17. S

    GLOW WORM SWIFTFLOW 100 COMBI

    This is a very early model with the constant pilot. The fan and gas valve were replaced last year and now theres another problem, the flame is dropping out intermittently in both hot water and/or heating mode theres a loud clicking when this happens I assume this is the solenoid on the gas...