  1. P

    worcester 28cdi ignition fault

    Thanks to everyone who replied to my query with the 28cdi and particularly the forum tip. Polarity and earthing were all fine the problem was with the contact between the multi plug and the board despite continuity in the sensor cable.
  2. P

    Bathroom extractor fan in celing as opposed to wall

    Yes use a duct fan as mentioned I have fitted loads and never had a problem with condensation anywhere. My tip is to suspend the fan from the roof trusses rather than fix to the joists then no vibration and hardly any noise.
  3. P

    worcester 28cdi ignition fault

    I am a retired gas installer and, while no longer registered, consider myself competent to do my own service and repairs. Have carried out fault finding on boilers for years but have never come across this problem, hence the question.
  4. P

    worcester 28cdi ignition fault

    This boiler lights perfectly on hot water or central heating demand but the spark continues and the boiler locks out. The manual, after carrying out continuity and position checks for the flame sensor, says replace the circuit board. I have access to an identical boiler and have fitted the...