Search results

  1. C

    Alpha CB28x Diaphragm replacement

    What is the fastest way of replacing a defective diaphragm on a CB28x ? Is it possible to remove the pump to gain access to the flow valve assembly then seperate the flow valve casing without physically removing the flow valve component?
  2. C

    Heatline Capriz 25 No hot water

    Just to clarify, the flow sensor is a 'hall effect' clip on part which fits over the flow sensor housing. This is the part that I have replaced. My understanding is that the paddle/turbine sits inside this housing and it is this that I need to gain access to. So my question is can the housing...
  3. C

    Heatline Capriz 25 No hot water

    CH is working perfectly but no DHW. Flow sensor replaced but problem still exists. Suspect that the flow paddle inside the flow senor housing is stuck. Question...can the housing and components be easily removed without draining down? Also, is there enough clearance without removing the gas...
Back