  1. W

    Extractor fan install - basic type no timer

    I would like to fit an extractor fan in the loft space above my shower room with ducting to the outside. I want it to come on when the light is switched on. The type i have is without a timer overrun. The instructions say to put a double pole switched connection unit in the circuit before the...
  2. W

    Notifiable work - socket & light relocation

    I would like to have a double socket relocated across a wall space in a bedroom and have the present ceiling light removed and instead have a couple of wall lights in the same room from the existing light switch. the room has a loft space above. I would also like an additional socket added to...
  3. W

    12V halogen downlight and transformer question

    I would like to install 5 x 12V Halogen lights using a DAIS DA-105 transformer. Each light is 20W. The Transformer states the MAX is 105W/VA. The instructions are not very good, so want some advice. 1. Can the transformer take this load ( 100W ) 2. The transformer has 3 outputs for lights...
  4. W

    9600 WATT shower - I want to have 2 fitted & advice need

    Hi all. I'm looking at having TWO Electric showers fitted at my property. I've seen what i would like and they are 9600 WATT at 230 V. I have a modern 17th edition split Consumer Unit installed already, with space for a couple of MCB's on each side. My supply Fuse is 100 AMP, my Consumer unit...
  5. W

    100A Main Service Fuse and 63 AMP rated RCD

    I'm soon to have an Electric Shower installed and i am going to purchase the parts required in advance and just pay for the labour costs on PART P sparky. I have been doing some research, my service fuse states 100A. My Fuse Board has no RCD protection. I will run the shower from a second...
  6. W

    Electric Shower trips the MCB do i need an RCD unit also?

    I need to replace my MCB to my Shower to a larger type. I have no RCD units. If i replace the MCB, do i have to also install and RCD (Have to get Electrician to do this). How does Part P relate to this as it's already installed some time ago, although i have no certs. I would use a PART P...
  7. W

    Washing Machine INDESIT WG113D Leaking Water

    INDESIT WG113D is leaking Water on fill at start of cycle at the rear of the Drum, looks like it could be coming from the Tension loop where a single bolt with a large Torx type head is securing it, no sign of any locking nut - so could this have come loose over time, not sure what the tension...
  8. W

    Advice on Kitchen Extractor from lighting and RCD.

    Hi, first post here - hope i'm in the right place. I'm having an Extractor fan installed in the Kitchen to run off of the lighting, so it will come on when the light is on and run on a timer for a while when lights are off - it is NOT to be used as an extractor for the Hob. My question is this -...