  1. H

    wiring for mains powered smoke alarms

    interconnect between the two alarms that is NOT live and neutral
  2. H

    wiring for mains powered smoke alarms

    Brown will be your live Blue your neutral and orange the interconnect between the two. Normally fed off of the lighting circuit but should ideally be on their own circuit.
  3. H

    Disaster - maybe

    If tested properly the values should be roughly the same all the way round .05 ohms variation I think is allowed. The only increases you should see are those from a spur which will be slightly higher
  4. H

    Disaster - maybe

    If a ring the values should not increase towards the mid point
  5. H

    alarms

    sorry texecom is the bell box with integrated strobe.
  6. H

    alarms

    Scantronic 9448+ or ade optima are both a doddle to wire and have plenty of features for what your after. Such as panic alarm, chime extra internal sounder etc. Any good wholesaler will stock them and I recommend a texecom oddessy 1 or 3 to go with whichever panel you decide upon...
  7. H

    Mobile phone masts

    How much do they pay?
  8. H

    .

    ---...---
  9. H

    Argos selling outdoor electricals

    My b+q certainly don't have trained electricians working for them. Was in their the other day on electrical isle. Someone asking what cable they needed to member of staff working on that section, he advised them they needed 4mm and this was for a 10.5Kw shower. You do the maths. I however...
  10. H

    Once upon a time

    between
  11. H

    Once upon a time

    ejaculating
  12. H

    Once upon a time

    of
  13. H

    Great Britains finest moment, What was it?

    2 world wars and 1 world cup :lol:
  14. H

    just a really quick question

    Fair point misread. As for B6 Lighting usually or ch alarm etc
  15. H

    just a really quick question

    Main switch fuse B6? Bit small aint it.
  16. H

    near misses

    Yeah agree with the last post, bs 3036's have their uses! Iv'e started to open the board and disconnect the live from the mcb tape end then close panel, just in case someone does turn back on, half the dip dops houses we have to work in can't read or can't be bothered to read if you leave a...
  17. H

    Becoming a spark

    To be honest Carloss if you are fully qualified then I would say you should be earning at least £9 per hour
  18. H

    near misses

    Yeah, a few months ago working in a council house. Tenant had tried to swap all switches for brass ones, messed it up in a major way and they ended up taking all face plates off an leaving it with protuded wires. My job being a coucil spark was to sort it out, went their and first thing I...
  19. H

    Light Levels dim

    Had a problem similar to this a while ago. Found the neutral bar in the consumer unit to be burning up due to a bad connection.
  20. H

    Shower Installation

    40A plug in mcb to 63A 30Ma rcd enclosure to 45A pull switch to new shower. All wiring in 10mm Twin and Earth. ok for 8.5Kw shower. Also supp bonding to pipes of shower if in copper.