    Worcester 280 hot water help please / UPDATE

    What are you expecting the temperature to be? What is the output of the boiler? You need to check the flow rate and the temperature rise.
  2. W

    calling oil experts

    Check P.E. cell
  3. W

    Glow-worm Compact 100e lock out problem

    Check your flow and return valves on boiler are fully open, and then check your rads for a by-pass route. Check that the thermistors are in the correct postion on the flow pipe.
  4. W

    Glow-worm Compact 100e lock out problem

    If you can check with the manual and check the wiring of the room stat to the boiler. I think you still need to check that the pump runs after the room stat has been turned down thus cooling the boiler.
  5. W

    Glow-worm Compact 100e lock out problem

    It could be overheating? But if you click off using the thermostat do you mean the stat on the boiler? If so then the pump should be over-running to cool the boiler. When you run the hot tap does this cool the boiler, so that it can be reset?
  6. W

    Vaillant 242EH intermittant hot water

    Get the manual it will tell you how to remove the diverter valve, a set of new O rings might help especially the ones for the pump.
  7. W

    Baxi Solo 3 PFL boiler keeps overheating!

    Do all of your rads have T.R.V.'s or is there a system by-pass, it sounds like there is no where for the water to circulate when the heating circuit shuts down. As mentioned by Stem.
  8. W

    Ariston Microcombi 23 MFFI (or 1)

    Is there 240V to pump? I think these have a differential pressure switch that makes when pump runs, so if pump not operating then nothing happens.
  9. W

    Potterton Suprima

    Mice?
  10. W

    constant buzzing

    Check the switch live voltage, if buzzing occurs when switch live voltage is not at full potential, then you may need to check you motorised valve.
  11. W

    greenstar 42cdi combi faul

    Check that the gas is on.
  12. W

    Baxi 105E Instant ch no hw

    http://www.partsarena.com/baxi/System/DATA/DS1/38/0@D@ED@KL@[email protected] fig44 are these parts O.K.
  13. W

    Worcester 28 cdi

    Check the gas is on?
  14. W

    combi boiler air lock??

    sounds like the tap washer?
  15. W

    Baxi (2) Solo 50PF

    Fitted a honeywell valve and now all O.K. It was the old type ACL valve without the removable head.
  16. W

    Baxi (2) Solo 50PF

    So whats the answer to this problem, just been to one today with this fault and the switch live is about 120Vac and P.C.B. relay is chattering until the valve moves completly over to heating then 240Vac then stops. Will a new ACL Drayton valve do the same, what about a Honeywell, anybody got an...
  17. W

    Boiler fault

    If the noise was coming from the bottom of the boiler it could be the P.C.B. try giving it a tap underneath (back right hand corner) if it fires up you will need a new P.C.B.
  18. W

    Baxi (2) Solo 50PF

    So whats the part no for the suppresor is it a baxi part? or is it on the board. If you have got 85-90 volts on switched live, then your valve is wired up wrong.
  19. W

    error code ariston he combi-boiler

    Boilers not working??????????????