    Stuart Turner Monsoon 4 Bar Twin Pump - HUNTING

    Hi The hot supply will be 3 bar as the cold feed to the megaflow will pass through a pressure reducing valve. If the pumped cold supply does not pass through this valve then the hot and cold will be unbalanced.
  2. S

    Radiators not working after refitting & bleeding

    If you get a rad working then let it circulate on its own for a bit then move on to another one. Get them working then balance the system. Once they are all working you can fine tune the balancing by opening / shutting valves accordingly.
  3. S

    shower waste

    Hi. If the extractor fan outlet is connecting into the soil pipe then this is illegal and needs to be removed.
  4. S

    Radiators not working after refitting & bleeding

    Each rad has two valves. One side a wheelhead or thermostatic valve and the other side a lockshield. A lockshield valve is one which you need to remove the cap to turn on and off. This is the valve that you use to balance the system. If both valves are wheelheads then choose the valve on the...
  5. S

    Radiators not working after refitting & bleeding

    Hi JayDee. Try shutting down the other radiators just leaving one of the cold rads open. This might push out any air or sludge thats causing a blockage. If this works then do it for the other cold rads. You will then need to balance the system. You do this by regulating the flow of water...