Search results

  1. M

    Removing part of a wall next to a steel

    Cheers, just had a thought that the roof people will sign it off with building regs so may send them some images to actually see if he will with those courses removed so near the steel. Thanks for the input
  2. M

    Removing part of a wall next to a steel

    And another angle from outside, the wall with the red cross is the one above the steels. I need to remove the 5 courses all around the flat roof.
  3. M

    Removing part of a wall next to a steel

    Yes that's a cavity wall, squeezed my hand in there and the steel finishes flush with the brickwork on show and not protruding into the cavity
  4. M

    Removing part of a wall next to a steel

    Sure...you can just see the steels at the top
  5. M

    Removing part of a wall next to a steel

    Yes, straight onto the wall...1970's house with the block work being those black clinkers on the steel. Would it not need a padstone as they are lightweight? No idea...I'm a sparky not a builder and this was uncovered yesterday when an asbestos ceiling was removed and now giving me grief with...
  6. M

    Removing part of a wall next to a steel

    Can anyone help with this? This is in my garage with a bedroom above to the left of the steels. To the right of the steels, with the loft insulation, is a flat felt roof that is being removed that extends a further 4m We are having a replacement solid conservatory roof that will extend over...
  7. M

    Firebird C20 burner

    Yes there's two lives at the plug. One from the limit stat and the other from the pressure switch. Pressure loss makes sense, it dropped and disconnected the c/box. When I raised the pressure with filler loop it put power back onto the c/box where I've been checking.
  8. M

    Firebird C20 burner

    I lifted the lid on the c/box to check. Oh well I'll see if I can pick one up tomorrow, back to the kettle filling :) Cheers for the help.
  9. M

    Firebird C20 burner

    Ok fair enough So are these prone to failure after 3 years? And I take it the drop in pressure was just a coincidence?
  10. M

    Firebird C20 burner

    Yes I unplugged the supply to the control box as couldn't get probes on to check voltage. No voltage going to the motor though. Control box shagged? Can't see anything else connected to it to tell it to run.
  11. M

    Firebird C20 burner

    Yes Terry, The enviromax combi with the MO 535 MPF control box fitted.
  12. M

    Firebird C20 burner

    I have and it took me to the control box. it has a supply present, I take it the photoresistance looks for the flame so I can disregard that as it's not firing anyway, the oil valve looks to be a solenoid to give the burner oil, a motor for the fan and ignition electrodes. I'm getting low on...
  13. M

    Firebird C20 burner

    Hi, Anyone familiar with the Firebird C20 oil boiler? Been away for 3 weeks and I usually switch it off but this time left it on. Got home Wednesday and the shower had hot water until Saturday morning then went Luke warm, checked the pressure gauge on the boiler and it had dropped just into...
  14. M

    Soil pipe adaptor for asbestos cement.

    Thanks for he reply Hugh, I think you helped me before when my old boiler ran out of oil........new one being fitted Monday :D Yep mask, goggles, full paper suit, hose in one hand and hacksaw in the other, nice and slowly. I'm not going to start attacking it with a grinder. I'll google...
  15. M

    Soil pipe adaptor for asbestos cement.

    Chaps.....I'm ripping my bathroom out in a few weeks and everything will be going back in a new position. This involves changing the soil pipe outside to accomodate all the new waste pipes, no problems with that but currently I have a what looks like a asbestos cement soilpipe. I need to cut...
  16. Untitled

    Untitled

  17. Home

    Home

  18. M

    Trianco Redfyre 15/19 problem

    Thanks burnerman, the new install is totally seperate from this old one. i was running the old tank low so I dont have to transfer oil from one to the other( opposite ends of the house)
  19. M

    Trianco Redfyre 15/19 problem

    er deffo new boiler as it needs moving to under the stairs to make way for a kitchen extension and new bunded tank in a new position too. need to move it to get rid of the chimney to make bathroom bigger.
  20. M

    Trianco Redfyre 15/19 problem

    yep I disconnected the braided hose and no oil, got the wife outside :cry: to pull the plunger untill it pumped out then quickly shoved it back on and tightened it up. mopped up oil off floor switched it on and hid behind the door and it fired up :mrgreen: thanks
Back