    Replace and move NTE5c master socket

    Duly noted. Have a pair of snips around here somewhere. Appreciate the heads up against spiked fingers and knowing me that would have happened!
  2. A

    Replace and move NTE5c master socket

    Thanks very much. Parts ordered Andy
  3. A

    Replace and move NTE5c master socket

    Hi, I need to move a master socket that enters via the top door frame. Currently connects via external black cable to a BT connection box and from this white cable runs down the doorframe to the master socket. Black green white orange from external cable This connects to orange green brown blue...
  4. A

    Worcester Heatslave 18/25 not firing

    Ok I was a numbnuts! External fuel liine fire safety valve had cut in as I must have pushed the copper end to close to the firebox. Reset the valve and all good.
  5. A

    Worcester Heatslave 18/25 not firing

    Back. Worked fine over night. Put all the casing back together now goes to lockout. Oilpump is running but unlike yesterday tigerloop is not filling What happended from last night to now I have no idea. Very frustrating
  6. A

    Worcester Heatslave 18/25 not firing

    Just one last question, what would cause the overheat stats to kick in?
  7. A

    Worcester Heatslave 18/25 not firing

    Hi Terry, I had tried those before I had changed the oil pipes from the tigerloop but not since. I have just tried them again and the boiler has fired up. I will see if it now heats up the radiators but looking good. Thanks to all for your help! As I said before it has rid me of my fear about...
  8. A

    Worcester Heatslave 18/25 not firing

    There is the reset button below the water temperature dial on the control panel. Fist thing I tried. My reset buttons are not on the boiler housing but a seperate unit on the wall. I tried these also but does not even go to lockout. I imagine now that it must be the solenoid or oil pump. Happy...
  9. A

    Worcester Heatslave 18/25 not firing

    Thank Oilhead now fully understood. Update. Changed the damaged pipes from the tigerloop but when boiler turned on Tigerloop is not priming with oil. Stripped down the boiler, removed burner to access screws to the control box, unplugged photocell and tried to restart boiler. Still nothing...
  10. A

    Worcester Heatslave 18/25 not firing

    Thanks I will do that. Before I do need a quick education on tigerloops. Gravity fed oil run out free flow. Tigerloop facing it two pipes. Pipe one and two connect to the oil pump. pipe two is first connected to a shut off lever. When I undo the connection to check the oil there is no flow. Can...
  11. A

    Worcester Heatslave 18/25 not firing

    RDB 2.2 Greendale burner. Not the usual Riello red casing though. Photocell does not connect to the control box and can' see where it connects unless I remove the control box and burner. Not going to manage that with my 2 year old daughter running around. No other reset button s under the...
  12. A

    Worcester Heatslave 18/25 not firing

    Thanks Bosswhite. Will check the photocell first and if that fails will look at the oil. Tigerloop is full of oil would that not indicate good oil flow. Previous boiler was gravity fed so not sure if indicates flow ok. What would e the easiest way to check oil is flowing to the pump? Tigerloop...
  13. A

    Worcester Heatslave 18/25 not firing

    Thanks Oilhead. Will try this when I get home from work tonight and let you know.
  14. A

    Worcester Heatslave 18/25 not firing

    Thanks for the tip. Unplugged but was spotless, cleaned anyway but no life. I can hear power to diverter. vibrates but nothing else happening.
  15. A

    Worcester Heatslave 18/25 not firing

    Direct wired Honeywell thermostat working. Calls for heat and hot water. Full oil tank. Tigerloop has oil. Boiler just stoped working. Does not lock out. I can hear the switch and then a gentle fan noise but no pump action therefore does not even try to fire up. Resets do nothing. Hard to know...
  16. A

    Smeg Dishwasher DWI64 Error Code E2 and PO and PC Help!

    I have a smeg fully integrated dishwasher DWI64 There was an item pushed against the side inlet, so got an error E2 I tried the reset process, switch of press P 4 times switch off wait 20s on and off again etc. Now it gets strange I press the power button, it comes up with 13 and the clock...
Back
Top