    Radiators cold upstairs , warm down stairs

    Hi i went to a job in a rented 2 floor flat the boiler is down stairs and they had no heat at all to rads upstairs, some down stairs i replaced the trvs as quite a few had jammed, the downstairs ones come on but had to turn them off one by one to get heat upstairs but then when i opened them all...
  2. M

    Triton madrid 2 shower hot and cold problems

    Hello i have had a triton madrid 2 shower installed last week, it has suddenly started to run hot and cold really inconsistent any ideas?
  3. M

    Bath mixer tap problems

    Hi there im looking for the best solution to sort out the temperature on a bath mixer tap/ shower. The tap itself when you turn it on to full rate only gets lukewarm at best, now when you feel behind the outlet on the body of the tap its really hot, so i checked the system out they have a combi...
  4. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Cheers mate im gonna have another crack at it im the morning, will look at that, boiler came on and fan operate, think it tried to spark just the once an then both lights would be flashing red, no ignition
  5. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Boiler is back on but wont fire any ideas?
  6. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Clear fuse looks ok, got 230 incoming to the board now too
  7. M

    Worcester 24cdi hot water problem diaphram diverter valve

    The power is off now the boiler wont come on just keep tryin with the hairdryer?
  8. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Hi i have jus flicked it on an it came on an then switched off again, i think it still might have had water on the electrics have i ruined it
  9. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Hi ive taken the divertor valvle apart but i cant remember which way the diaphram goes in, is the two sprins facing the cover side?
  10. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Cheers mate nice one im gonna download an print a few pages out the manual just to help, its a job for family and im off work tommorow so got all day to do it, is it worth getting some lubricant for the o rings too? will it be ok to open the drain valves on the boiler or will they leak too?
  11. M

    Worcester 24cdi hot water problem diaphram diverter valve

    i am trade mate, was just wandering if it could be done bought a set of 90 degree screwdrivers for it, got extra o rings for the job too heard these can be a nightmare, which parts is it i have to take out to get too, Filling loop an heat ex is that right?
  12. M

    Worcester 24cdi hot water problem diaphram diverter valve

    Hi everyone im changing a diaphram on a diverter valve tommorow heard its a bit of a pain job to do, any advice and can it be done in situ with out taking other parts out? thanks
  13. M

    Ideal Isar HE 24 not firing up , no heating no hot water

    Cheers just to let you know i changed the pcb, spark generator and ignition electrode and it fired up working the screen was fixed with the pcb change, looks like it was caused by a leak from the aav with the cap not being on so will have to get a new one of them too. Thanks for your help
  14. M

    Ideal Isar HE 24 not firing up , no heating no hot water

    Hi I am gas reg but not experienced in fixing boilers I was looking maybe towards the spark generator and ignition electrode, but you think maybe fan and pcb
  15. M

    Ideal Isar HE 24 not firing up , no heating no hot water

    Hi my dad has an ideal he24 and a few months ago the itimer programmer (lcd display) on the boiler suddenly went blank an showed no display, now the boiler when turned on is just making a humming noise its just will not ignite or fire up, any ideas on the display? and the boiler itself? thanks