  1. X

    Seeking advice on upgrading heating system

    Hi. Apologies for what may seem a rambling post - I'm currently trying to improve my knowledge and assess my options and would be grateful for any thoughts. I live in a large old property which is currently heated by an ancient regular oil boiler (Ideal De Dietrich Falcon GT) in the basement...
  2. X

    Using Hive on 2 separate boilers?

    And the final verdict: works perfectly :) Thanks for your input everyone.
  3. X

    Using Hive on 2 separate boilers?

    I can't find the manual for it (Ideal De Deitrich Falcon GT). It is extremely old! The later version says that it needs a 5 min overrun, but I guess that if this one doesn't even have the facility, then it doesn't really need one. I thought it might be a good idea rather than dumping extra...
  4. X

    Using Hive on 2 separate boilers?

    I'm still having probs with this... As shown on one of the pics I put up previously, the boiler has connections for a pump and a thermostat. I've wired up a simple test thermostat (simple on/off switch), which works as expected - turn the switch on and the burner fires up, turn it off and it...
  5. X

    Using Hive on 2 separate boilers?

    Ha, we've got a shower in the static! I got a dual channel hive for the house as I'm not sure what heating system we'll have in the future when it's done, but for now, we mostly freeze in the static, lol!
  6. X

    Using Hive on 2 separate boilers?

    Sparky been and reckons should be fine to put the Hive straight into the boiler terminals, and run the pump from the boiler terminals too, ripping the rest of the unneeded stuff out.
  7. X

    Using Hive on 2 separate boilers?

    I've managed to get proper access to the wiring in the boiler now, and it looks as though it can take a thermostat, and also control the pump! I guess it can run the pump straight from there withouth a relay? (Pump is 140w / 0.62A.) Don't like the look of the black wire going into a "L"...
  8. X

    Using Hive on 2 separate boilers?

    There's only one heating zone - there's no diverter valves or anything like that, and def no heating in the attic! I'm sure that's just a low temp sensor and can get ripped out, along with the outside sensor. I'm pretty sure you're right about scrapping the existing wiring and installing the...
  9. X

    Using Hive on 2 separate boilers?

    The outside thermostat is just monitoring air temp as far as I can see. It's high on an outside wall. Weather compensation maybe - I don't know the technicalities. I do know that the one in the attic has a dial on it, same as the one in the main room. No, none of these are for the LPG...
  10. X

    Using Hive on 2 separate boilers?

    The 3 thermostats in the house are main room, attic and outside air, so I'm guessing the attic and outside air ones are low temp sensors and can go, just leaving the one in the main room, which I'm planning to swap to the receiver (which would then be hard-wired to the boiler, using the existing...
  11. X

    Using Hive on 2 separate boilers?

    Think I might be getting somewhere now, found this in the depths of the boiler:
  12. X

    Using Hive on 2 separate boilers?

    So here's my challenge for today, fitting Hive onto this beast! Sparky booked for 5pm if I can't figure it out before then! There are 3 thermostats in the house, one in the attic, one outside and one in the main room. I'm thinking to hijack the one in the main room for the receiver so it...
  13. X

    Using Hive on 2 separate boilers?

    There's 3 thermostats, 2 pumps, one holiday switch, 2 isolating switches, a mechanical time switch, an archaic boiler with a newish burner and 3' stone walls in the basement to contend with! I'll do a wiring diagram ready for tomorrow.
  14. X

    Using Hive on 2 separate boilers?

    Thanks all, still sounding positive so far then! The house boiler will be a pain to wire (hope it's possible!) as it's an old commercial one! Will update tomorrow.
  15. X

    Using Hive on 2 separate boilers?

    Thanks for the reply. I can't see why it wouldn't work either. The first chap at Hive didn't know, so went to ask a colleague then came back and said no, but didn't say why. I installed the Hive in the static as it was straightforward, but the boiler in the house is more complex, so I've got a...
  16. X

    Using Hive on 2 separate boilers?

    Hi, I've got a house with an oil boiler, and a static out the back with an LPG boiler. Do you reckon I could get a Hive Multizone system to control them individually? Or would it be a case of having 2 totally separate Hive systems, so 2 Hive hubs plugged into my router and 2 separate logins...
  17. X

    Wiring Hive Smart Thermostat to Combi Boiler

    Just wanted to say thanks very much for this thread - I've just installed the same smart thermostat on the same boiler, and it's working perfectly :)
  18. X

    Please recommend me a sealant!

    Thanks all, much appreciated :)
  19. X

    Please recommend me a sealant!

    I've got an Ifor Williams horse trailer, and a very common problem on these is that water gets in where the side panel sits on the chassis, and stays there and rots the panel. Ifor Williams do apply sealant at the factory, but it comes off. I've resealed it myself, but it comes off (pic...
  20. Untitled