Search results

  1. U

    Intergas HRE 36/40 DHW demand issue

    Hi guy's, Hopefully someone can provide some assistance. Moved in to property which has a intervals HRE 36/40 installed and having an issue with the boiler. It seems to be constantly seeing DHW demand. Cycles from 1,4,3,6 (temp reached, ignite, vent, DWH) Won't switch from this into CH mode...
  2. U

    Biasi - Riva HE M96 28SM/C - Ignition Error

    Fair enough FYI As i said before i'm not intending to open the chamber. I know a corgi fitter who is unfamiliar with Biasi boilers, he can install not troubleshoot them. So if i could tell him to just fit the detection electrode if this is the cause - the fix would cost me £100 inc...
  3. U

    Biasi - Riva HE M96 28SM/C - Ignition Error

    Thanks Agile, Yes it's the one with a separate ignition PCB Please don't shoot me down, however; I have the option to pay Biasi a fixed fee of £200 and they will fix including the parts and labor - not a bad deal i think if the parts become expensive (PCB) Looking at the fault last...
  4. U

    Biasi - Riva HE M96 28SM/C - Ignition Error

    Thanks Agile, i'm definitely not opening the gas / seals. Just wanted to check if this is the problem area or if i can do any further troubleshooting to try and identify the issue. Reading though various posts, some advise this is a PCB issue, which i would consider doing myself. drain...
  5. U

    Biasi - Riva HE M96 28SM/C - Ignition Error

    Hi Guys, wondering if anyone can help i have a Biasi Riva Compact HE M96 28SM/C it's been working fine for years However over the last 2 days will keep locking out with the error indicating 'lack of burner ignition (no ignition signal from the full sequence ignition device)'...
Back