Search results

  1. J

    CH going off randomly

    Just in case it helps... Even when the CH is not working properly, the HW works fine. Boiler fires up and heats water. Still no heat at the rads though. There are two motorised valves under the floorboards, any chance they could cause this problem? Thanks, John.
  2. J

    CH going off randomly

    Thanks for the company chaps. No room thermostat fitted (yet). The programmer always indicates what the situation should be i.e. CH light lit, but no heat at any rad until it resolves itself. May be coincidence, but I think it may have gone off when the hot water kicked in. Any help...
  3. J

    CH going off randomly

    Hi All, Boiler is Glowworm Fuelsaver 50R MkII, GC number 41 313 79. The system works 90% of the time switching both HW and CH as required. However, on occasions, the central heating doesn't come on when programmed or the central heating comes on and then goes off despite what the...
  4. J

    Glowworm Fuelsaver MkII (Model 50R) Tepid Radiators

    Just to close this thread, I did eventually resolve this problem. As a last resort I planned to repeat the power flush (from the pump location) and at the same time fit a new central heating pump. However, it seemed sensible to replace the pump first, since it was the lower cost of the two...
  5. J

    Granite Tile Finish

    Thanks Mudster, disappointing though that is. Any advice on how to get the tile up? (if I work up the courage).
  6. J

    Granite Tile Finish

    Hi, we've had some black granite tiles fitted to the bathroom. Unfortunately the tiler finished in the half-light and didn't notice one tile was different to the rest! We now have a single tile with a dull, black surface and no metallic fleck in the finish. The compounding problem is that we...
  7. J

    Glowworm Fuelsaver MkII (Model 50R) Tepid Radiators

    Hi, I've got a gas Glowworm Fuelsaver MkII (Model 50R). An approximate sizing has shown that the boiler output is just enough (theoretically) for the original radiators and a double panelled one added recently. The central heating has been poor for a while with downstairs radiators being...
  8. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Oops, but by-passed by a Corgi man until he can fit the replacement! :shock: John. p.s. Well done Chris.
  9. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Ok, I believe it's fixed. The problem was eventually tracked down to a broken overheat thermostat. It's probable that when the boiler was turned on during the flushing process, it wasn't adequately filled and triggered the cutout. I assume this is why it burned in 15 second bursts. However...
  10. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Chris, the boiler is a 50R MkII, GC number 41 313 79.
  11. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Thanks Guys for your attention on this, this isn't my area of expertise, so please bear with my inexperience. When I re-tested the new thermostat, I found that one of the thermostat block terminals was live which was not live on the old one. So I've fitted it permenently now. When the...
  12. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Thanks for all the responses. Just to answer the questions (as best I can) and clarify the position. 1. The flow and return pipes leave the boiler at the top. They continue to rise. There is a vent (vertical pipe with screw top alongside the hot water tank) in the roof space, which has been...
  13. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Oh, and the pump is working!
  14. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Thanks for the suggestions, I've looked on the website for documentation, but it's an old model and I couldn't find any references. I'll check again. The system was fully bled (as far as radiators go), is there anything else to bleed?
  15. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Thanks for that, unfortunately the previous owner left me no documentation!
  16. J

    Glowworm Fuelsaver MkII Main Burner Not Lighting

    Hi, I've got a gas Glowworm Fuelsaver MkII (Model 50R) and the main burner is no longer igniting. The central heating has been poorly for a while with odd radiators being cold and the boiler being noisy when first switched on in the morning. When the system was drained, cleaned with Fernox...
Back
Top