Search results

  1. S

    Removing floor tiles, possibly asbestos?

    Certain types of older vinyl tiles did contain asbestos, and the adhesive used. if your dead set on removing them, check out the HSE website, useful references to PPE. it sounds like they are well stuck though? could you not just leave them in place and latex over them??
  2. S

    Flat roof edging worry

    My god that's shed felt isn't it? proper rough!
  3. S

    Blade reducers

    Hire a 4 1/2" grinder with a diamond blade, you can dry cut, hot knife through butter!!
  4. S

    Garage personal door

    If it's external, which I assume it is, you should be looking at hardwood door and frame. Haven't looked at your pic's but an external frame will come with threshold fitted, just make sure you choose an opening in frame!! Select a door to suit your new frame and away you go! Good luck with it.
  5. S

    New boiler & pump runs contiuously

    That's the thing, I don't think they are, tank stat is set at 50, the room stat isn't calling, and the boiler stat is set at 75. So I would have guessed the tank would be at temp after not running any HW for a couple of hours????
  6. S

    New boiler & pump runs contiuously

    Hi there after some advice, I had a new boiler fitted 6 months ago, Glow Worm 15HXI, they also fitted a new 3 port valve, I have only just realised that the external pump appears to run continuously whilst the system is on, when the time clock switches off, so does the pump. is it normal for...
  7. S

    Time served joiner by trade, now working as a site manager.

    Time served joiner by trade, now working as a site manager.
  8. S

    Load bearing wall or not?

    Just out of curiosity, is this wall roughly central along the length of the elevation your house?
  9. S

    Load bearing wall or not?

    Just out of curiosity, is this wall roughly central along the length of the elevation your house?
  10. S

    New boiler / controls not working correctly

    Hi gas, valve is existing, seemed to work OK with previous boiler.
  11. S

    New boiler / controls not working correctly

    Hi all, hopefully someone can shed some light on my problem. I had a new glow worm heat only boiler fitted 2 months ago, I have just noticed, as I am home all day on hols, during the day with the boiler switched on, stat is calling for heat but boiler is not heating CH, until I run enough hot...
  12. S

    New boiler / controls not working correctly

    Hi all, hopefully someone can shed some light on my problem. I had a new glow worm heat only boiler fitted 2 months ago, I have just noticed, as I am home all day on hols, during the day with the boiler switched on, stat is calling for heat but boiler is not heating CH, until I run enough hot...