Search results

  1. F

    Problem with Valor Eminence Model 762 Gas Fire

    Your valuable advice is much appreciated. Thanks
  2. F

    Problem with Valor Eminence Model 762 Gas Fire

    Hello to all fellow members. I am dealing with a problem with a Valor Eminence Model Gas Fire. It developed the fault gradually as I have tried to explain in the following; Initially, it failed to ignite pilot flame despite replacement of new batteries in its receiver and remote control. I was...
  3. F

    Cental Heating Issue

    I am pleased to let everybody know that I have resolved the problem successfully by using this platform. CROSS THREAD & CBW who have jointly guided me to root cause of the issue and how to check it respectively. There was a Loose connection to an oxidised live lead to thermostat from the...
  4. F

    Cental Heating Issue

    No,I haven’t. Would you advise me what is the best process to check the continuity of the thermostat please.
  5. F

    Cental Heating Issue

    Yes there is a thermostat. I have tested the junction box with thermostat on ie maximum temperature position.
  6. F

    Cental Heating Issue

    Hello to all. Central Heating cooled down a few days ago, the diverter valve Drayton ZA5 controlling central heating appeared malfunctioned. I have tried to operate manually but did not remain on. I removed its head and turned the central heating on by opening the valve manually whilst Hot...
  7. F

    Creda T632CW Dryer

    Firstly I would like to thank fellow forum member Yardie who helped me throughout in resolving the problems with my Creda dryer. Secondly I would like to update you now. I checked the front thermostat and drying sensor, both of the component were found functioning satisfactorily. After having...
  8. F

    Creda T632CW Dryer

    Its heater definitely does not turn on. No, sorry I have not managed to locate the exhaust stat and drying sensor yet
  9. F

    Creda T632CW Dryer

    I have connected a flexi hose pipe and feed it into the washing machine drain pipe but during all of the currant repair procedure I have have left the flexi pipe into a bucket on the floor as the dryer is placed on a shelf above washing machine. I have tried it twice with cloths on sensor...
  10. F

    Creda T632CW Dryer

    I have tried it at the sensor setting loaded with cloths taken out of washing machine. It ran about 55 mins. At the end cloths were nearly dry but cold the heater did not turn on throughout the cycle. I have checked the water tank overflow sensor. The machine halted when its overflow sensor was...
  11. F

    Creda T632CW Dryer

    Sorry I am at work at the moment. I did not get a chance to try at other setting with damped clothes loaded in. I will try later on after the work and let you know the outcome. It did not have any problem with heating. In fact the element was glowing red hot whilst I was resolving the motor...
  12. F

    Creda T632CW Dryer

    Thank you very much for your advice. I will try tomorrow and let you know the outcome.
  13. F

    Creda T632CW Dryer

    I have been trying at 30 mins drying programme. I will try it at other modes tomorrow. i can not turn it on now because my because my two years old grand children are asleep now. I will try and let you know tomorrow
  14. F

    Creda T632CW Dryer

    Yes it is sensor dry.
  15. F

    Creda T632CW Dryer

    Yes it is condenser dryer. Where is the exhaust thermostat located?
  16. F

    Creda T632CW Dryer

    Yes it is 24v double pole switched relay. I did test it last time and I have tested it now. It activates as 18v is applied to its coil. The both of single pole relays work when machine is turned on but the third double pole switched relay does not activate therefore J3 terminal remains dead...
  17. F

    Creda T632CW Dryer

    I have monitored voltage at the third relay which feeds to J3 which is connected to the one side of the double pole switch of the relay, which was found in Off position as the side of the switch is On position with mains voltage.
  18. F

    Creda T632CW Dryer

    It is direct from the pcb. J3 (terminal of double pole switched Relay) via black/white wire to connector and from connector to one of the stat 1 via Grey wire. From mains neutral via blue/white to connector and from connector to stat 2 via orange wire. Should J3 relay controlled terminal be the...
  19. F

    Creda T632CW Dryer

    I have checked all of the connections again. The machined spins both directions but there is no supply to the thermostat during any cycle. Does any of the three relays supply power to the heating elements?
  20. F

    Creda T632CW Dryer

    Thank you for your prompt response. Yes it was heating up before. I will act on your advice and keep you posted.
Back