Search results

  1. G

    Worcester Greenstar Junior 28i leaking - advice needed

    I just thought I'd answer my own question in case anyone else stumbles upon this... The culprit was the return unit as suspected (part No. 8 716 106 442 0) and the PRV was also leaking. To replace it I removed the hydraulic block to make t easier to work on. The replacement part only comes...
  2. G

    Worcester Greenstar Junior 28i leaking - advice needed

    Righto, removed the flow adapter and it basically disintegrated in my hand, I cleaned the bits out of the return manifold and fitted a new adapter wit fresh O rings but it's still leaking out of the unused port!!(but not nearly as much) I can only assume that the plastic in the housing is also...
  3. G

    Worcester Greenstar Junior 28i leaking - advice needed

    Thanks for he reply, if the flow adapter is the part causing the leak would the water be rising up out of the unused port? I hope so as this looks like a much easier fix! :)
  4. G

    Worcester Greenstar Junior 28i leaking - advice needed

    Hi all, I'll try to keep this as brief as possible and thanks to everyone in advance that can offer advice. I have a Worcester Bosch greenstar Junior 28i combi boiler fitted mid 2011. It's leaking from the 'unused port' situated just on top of/behind the flow turbine on the return manifold (on...
Back