  1. A

    Can I do this?

    I want to baton plasterboard an external facing internal wall and then gypsum wet plaster the adjoining internal facing internal wall. Can this be done? Any potential problems where the gypsum meets plasterboard. Probably best to attach batons, then wet plaster adjoining wall and then after...
  2. A

    Sand and Cementing Internal walls of old properties.

    My older property is plastered inside and out with lime plaster. I need to replaster large cubboard in Kitchen with one external wall and 2 internal walls. The lime render of the exterior of the property is in good condition and my flat has never suffered from damp. My preferred method of...
  3. A

    1903 property, plastering large cubboard, which technique best

    I live in a 1903 sandstone first floor tenement flat. I need to plaster a large cubboard (6ft by 5ft by 2.5ft) which will house a combiboiler. What will be the best technique to plaster it? My flat has no problems with damp but it is a priority of mine to have this continue. 2 walls are...
  4. A

    2 wires in 1 terminal on switch

    Thanks phatboy. So the terminal screw closing on 2 wires side by side should give a solid connection?
  5. A

    2 wires in 1 terminal on switch

    Is it good practice to insert 2 wires side by side in 1 terminal of switch. In my example the 2 wires would be the common wire and a feeder wire to another switch. Any responses appreciated.
  6. A

    changing one gang dimmer switch.

    Securespark. So your saying that the old switch was wired up in the opposite way it should have been. But the lights worked perfectly for many years.
  7. A

    changing one gang dimmer switch.

    Thanks for all your help. Securespark Yes intertwined meant I was meaning twisted together. I don,t follow your later point about when the feed to other room goes when I split these wires. What should happen to the 3 wires, which goes to common and which to L1.???
  8. A

    changing one gang dimmer switch.

    To update I believe the reason the two wires were intertwined was that this switch was feeding another switch in another room. Now that I have separated the 2 wires, the light in my bedroom doesn't work. So how does this new information help. So I need to keep these 2 wires connected together...
  9. A

    changing one gang dimmer switch.

    Need to change my dimmer switch in livingroom. It is the only switch that controls the livingroom lights. On taking out the old switch I see their are 3 wires which were connected to it. There was the common wire, going into common terminal, and then 2 other wires both intertwined and going into...
  10. A

    gurgling boiler when i empty kitchen sink

    Yes it has just started. The boiler only gargles when I drain the sink very quickly with a lot of water in it. Can I easily check for blockages in the condensation and drain pipe by myself or do I need a pro for this. This gargling developed after my feeding loop was stuck open overnight...
  11. A

    damp proof course in 1903 block of flats

    My block of flats and the others on my street are all made with sandstone dating from 1905. Their seems to be a foundation of another stone in the ground below the sandstone. I am thinking this other stone is designed as some sort of damp proof course.Will this be the case and what kind of stone...
  12. A

    gurgling boiler when i empty kitchen sink

    gurgling noise from boiler when kitchen sink is emptied. my boilers overflow pipe is connected to the sink drainage. i recently had my boiler overflowing. any ideas on a solution? it is a two year old modern combi boiler, the vokera compact 25 model. thanks
  13. A

    No stop cock for boiler.

    If indeed the double check valve is broken (at moment I am hoping only the feed valve is broken) how would I know?? Can I test it easily? Thanks again.
  14. A

    No stop cock for boiler.

    Thankyou folks, I have found mains stopcock, it was at almost at ceiling height next to old water tank. Have relieved pressure and taken off broken feeding loop. I will only attempt to replace the broken valve in the loop with the help of some PTFE tape.
  15. A

    No stop cock for boiler.

    I have a vokera compact 25 boiler. I need to find the stopcock which is feeding the feeding loop, turn it off and then bleed my radiators to relieve pressure (I think).
  16. A

    No stop cock for boiler.

    I have a stopccock under my kitchen sink which turns off the cold water taps only, but not the hot water tap which comes from my 2 year old combiboiler. Am I right in thinking there must be a second stop cock somewhere that controls my hot water from combiboiler.
  17. A

    Cannot lower pressure on boiler

    I don,t know how to turn off mains. Have one stopcock which controls cold water only.
  18. A

    Cannot lower pressure on boiler

    I opened filling loop and now pressure has gone to 3.5. Cannot lower it, it just increases again after bleeding radiators. The filling loop has only one tap. I had to use spanner to open filling loop and actually turned opener 360' even though its only a quarter-turn valve. I cannot turn water...