  1. S

    no hw/ch

    thanks for the replies, sorry if it was unclear and after having a second look it does seem more a fault on the boiler than any thing else, yes the boiler fires up but not to full power if you see what i mean..??
  2. S

    no hw/ch

    have an ideal classic lxff boiler and everything was fine untill yestersday and this morning no hw or ch boiler does fir up when we turn the heating or hot water on and pump runs and when you just ask for hw the valve does move a neighbour said he had same prob last year and they replaced the 3...
  3. S

    51 plate transit diesel engine cutting out

    hi all, i have a prob with my transit cutting out all the time especially when cold and when reversing, a soon as you put any revs on the red immobiliser light flashes and engine cuts out and ideas appreciated in the past month its had new pump, new filter and new fuel pipes...???
  4. S

    heating probs

    hi all, to start with i had a slight leak from my central heating pump so called a plumber, he came and replaced the pump and the 2 valves, turned every thing back on and away he went, came home house cold no heating, called him back he came out for the next 11 days until i said forget it i'll...
  5. S

    aqualisa aquavalve

    just been to a leaking concealed aquavalve probably around 10 - 15 years old and the hot water is is constantly dripping out does any one no off hand if these can be repaired or is it a case of a new valve..?? thanks
  6. S

    cold water cistern

    woops didnt see the end bit
  7. S

    cold water cistern

    cheers chris so would you say go for a 50 then..??
  8. S

    Is corgi registered required?

    where abouts in cheshire you from ???
  9. S

    cold water cistern

    what size of cistern tank would you recommend when fitting a 2.2 bar pump for a mixer shower as the one in at the mo is 25 gallon so was thinking around 42 as it will also have to feed a bath/shower mixer tap which has to have an independent feed for the cold rather than direct mains... thanks
  10. S

    servis

    hi all, just had a call from a client of mine and she says her washing machine is making her clothes go like a rusty colour..??? she says her dad said the belt is on its way out..!!! all i know is that its a servis about 3 years old and she said its spinning on empty and when full...
  11. S

    electric shower installations

    hi all, are we allowed to replace a like for like swap electric shower under part p regulations..??? never normally do them but customer wants one asap and wasn't really sure where i stood as on a new installation i just leave it to the spark to connect up... cheers
  12. S

    waste pipe run

    cheers nige and kev so do hep do a smaller one for the shower..??
  13. S

    waste pipe run

    hi all just about to add a bath to the far side of an en-suite it a roll top one so its connected via the hep 2o waste valve now the thing is is at the end of the run i have to join in the shower waste pipe as there is only room for one boss, would this cause any probs as in bath water entering...
  14. S

    fitting bath taps to roll top bath

    what is the easiest way to fit the taps and pipe work for the roll top baths and baths that have the taps in the centre against the wall...???
  15. S

    boosting bath mixer shower

    the c/w tank is sat directly on top of the h/w cylinder in the bathroom and the shower head off the bath mixer is above the height of the c/w storage hence why there is so little pressure..?? well i presume thats why..
  16. S

    boosting bath mixer shower

    is it possible to fit a negative head pump to just run the bath and bath mixer shower..? customer has hardly any pressure and negative head, she cant afford a whole house pump etc or a shower pump combination, so i was thinking about running independant supplies to the bath via a 2 bar pump (neg...
  17. S

    installing a shower

    thermostatic mixer will do
  18. S

    compression fittings

    hi, i had the same problem last week as a customer had a broken pipe which happened to be that horrible marley blue, no fittings on the market fit it correctly and it will take three weeks before proper parts get here so i had tooo file it down and bang on a speedfit coupler just so they could...
  19. S

    pump to boost pressure

    is that what an equilibrium ball valve is for to stop the pump from running after flushing the wc..?? looks just like a torbeck valve
  20. S

    pump to boost pressure

    cheers chris i was hoping you'd reply, yeah just been looking at them online and gathered i'd need to get one for negative head, what bar would you recommend ?
Back
Top