    pyronix euro mini alarm activated

    Thanks sparkym I’ve retrieved the details from this morning and it’s saying the kitchen sensor activated ( input ) . No idea why it wouldn’t let me accept the alarm with my normal 4 digit code . Might change the sensor out anyway as the mrs needs the system working when I am away . I ll open the...
  2. C

    pyronix euro mini alarm activated

    HI, I have a Pyronix euro mini panel and system. When we go to bed we press YES and B. Lastnight the alarm sounder activated about 4 hours after being armed and the only red led I saw on the screen was " zone B" flashing. It didnt accept the normal 4 digit code. We had to put in the engineers...
  3. C

    Pythonix euro mini

    sparkymarka thanks and appreciated all back to normal . Neilc
  4. C

    Pythonix euro mini

    Sparkymarka , does he just put the 6 figure code in the engineer set or do anything after this . Appreciated assistance mate as we are away on holiday .
  5. C

    Pythonix euro mini

    Thanks I will get him to try the manager code tomorrow and get him to try the yes b and set .
  6. C

    Pythonix euro mini

    Hi I have a pyronix euro mini pad which is on exit entry and at night to set system . The engineer programmed it so on a night time we just pressed Yes + b going up the stairs to bed. I am on holiday and my son has accidentally pressed yes + d and he cannot get back to our original setting yes...
  7. C

    Indesit bwd71453 counter balance loose

    Our washing machine has been making an awful noise for 3 weeks. I ve just had the opportunity to take off the top cover and discovered the counter balance seems loose . I’ve tried the 10mm bolts and they are solid . Just a thought I wonder if the balance is depreciating hence why I can’t tighten...
  8. C

    Dyson 25 changeover valve

    my old Dyson 25 won’t change over to the tools and I think it’s related to the changeover valve . The vacuum works great and filters always changed and cleaned. I’ve enclosed a photo. Can someone tell me if that button should be inside the transparent changeover section ? If it is how do I get...
  9. C

    F50 Miele error

    Hi , I have a washing machine PW6065 and we presently have a F50 error at the end of the cycle and we find the clothes have not been spun properly. However if I accept the F50 error ( ok ) then put it on a spin only cycle it will do this no problem and spin the clothes as normal. The drain pump...
  10. C

    Connecting viessman vitodens 050 to hive

    No it was my choice probably should have researched it better, the boiler has ViCare but not really sure how that works. Hive receiver and hub to pair are a bit fiddly, sure I ll get the hang of it .
  11. C

    Connecting viessman vitodens 050 to hive

    All working now thanks :) not too pleased with hive , think i should have took viessmans advice and went for tado. However its working and we program schedules for the mrs. Thanks again.
  12. C

    Connecting viessman vitodens 050 to hive

    Hi we are a tad confused, so to the hive receiver we need 3 core cable , from 1 on the thermal back to 3 hive , live on hive to L on boiler x96 , and N on hive to N on x96 , with a link between L and 1 on boiler x96 . Thanks
  13. C

    Connecting viessman vitodens 050 to hive

    Thanks for this , most folk near where I live use hive and the gas fitter advised hive . Although viessman advised me tado . If I am not happy I can always change the control system. Thanks again and I ll let you know how we get on ok. Appreciated .
  14. C

    Connecting viessman vitodens 050 to hive

    Just wondering if the new hive system is opentherm or is it 240v switched ?
  15. C

    Connecting viessman vitodens 050 to hive

    Hi, Does anyone have any experience with connecting a new viessman vitodens 050 to a hive receiver. I’ve posted the book . It’s looking like we connect it to D for opentherm on viessman and hive receiver Connection 1 and 3 but i am not 100%. Help appreciated.
  16. C

    Vitodens 100 water no heating enough

    Thanks there’s a CH firm attending tonight it’s a 12 year old viessman vitodens which has never had a problem in all that time ( we’ve done well ) it’s serviced every year but if it’s costly to replace the CH heat exchanger might be worth changing it the boiler not sure what you guys would...
  17. C

    Vitodens 100 water no heating enough

    Hi , it’s trying to heat up and then drops off repeatedly.
  18. C

    Vitodens 100 water no heating enough

    He’s some more information. We tried the hot water from another position and it was heating up but then went cooler and tried to heat up again and then went cooler. When I felt the hot water outlet from boiler it was hot so it is trying but is working intermittently. Could this be diverter valve...