  1. S

    blue brick rsj pads

    about 7-8 '' over hang the steel girder will go 7-8 '' into the remaining wall either side it's a through lounge dinner that i'm trying to make. thanks for your reply masona !!!
  2. S

    blue brick rsj pads

    can anyone tell me how to use blue bricks for pads to sit a steel girder on ? how many do i need ? how do i put them in ? is it 3 blue bricks in a stack, 1 on top of the other ? for each end of the girder ?
  3. S

    though lounge / dinner

    THE HOUSE IS A 3 BED SEMI, THE WALL IS A DOUBLE THICKNESS LOADBEARING WALL, IT GOES UP TO THE LOFT FLOOR AND IS THE DIVIDING WALL FOR 2 BEDROOMS. IT IS SOLID ALL THE WAY UP. I WANT TO MAKE AN OPENING IN THE WALL DOWNSTAIRS TO JOIN THE LOUNGE TO THE DINING ROOM. CAN ANYBOBY HELP !!
  4. S

    though lounge / dinner

    can anyboby tell me what size steel girder i would need to make a 7' opening in an 11' wall, thats leaving a 2' peir each side of the opening. also how many blue bricks for the pads and how to arrange the blues. would i be right in saying the girder would need to be double boarded for fire...
  5. S

    building regs

    thanks for your help, and i will do what you have said and get the build regs people in to check it, cheers again steptoe...............
  6. S

    building regs

    i had an internal wall removed 2 years ago and was told by the builder that i did not need building regs approval or planning permission, a friend has now informed me that i should of got build regs as it was a structural wall. i cant find the builder that did the work. what do i do now...
  7. S

    FLOORBOARDS ON A CONCRETE FLOOR

    HI, can you help me i want to put floorboards in my living room, but it is a concrete floor . can i put them down as a flooting floor or do i have to baten the concrete floor then nail floor boards to the batens, or is their another way to do it. any info would be great cheers steptoe
  8. S

    floorboard removal

    you can also use a circular saw, i saw a plumber using one to do the same job as you mentioned.
  9. S

    replace shower help me

    cheers breezer. the seperate consumer unit says 30 amp on it, is this the amp rating of the switch inside the unit ? as i have seen the same c.u's in b&q that say 40 amp on them, would my 30 amp c.u. need swapping for the 40 amp unit or can i put the 40 amp mcb in the 30 amp c.u. if my c.u...
  10. S

    electrics - how do i check if current is flowing in a cable?

    does not matter which way round the red and black probes go. as it's ac ( alternating current ) it alternates above and below 0v. therefore there is no negative or positive sides. you can put the probes on the cable any way round . make sure that when handling this black cable that all...
  11. S

    replace shower help me

    my shower has a seprate wylex fuse box of it's own in my electric cupboard. it is rated at 30 amps switch with a 30 amp mcb fuse fitted. and runs to the shower on 6mm cable. the new shower i want to put in is a 9.5kw shower can anybody tell me if i need to change the wiring or fuses ?? the...