i am looking for an application that pulls customer addresses automaticly into invoices / quotes and so on with out me cutting and pasting my socks off lol,, words is ggood for letters but i want all in 1 program that is already configured. having a look at DIRECT ADMIN at the moment BUT it has...
i am about to go self- employed in the heating trade,, got pretty much everything thought of but i cant make my mind up when it comes to software, it needs to to the obvious things . invoicing, quotes, addressbook, payments received/ outstanding , header with flexible setup ie: inserting logos...
the isolation should be near the boiler,, as for any other bits and bobs,, try not to place them underneath any pipework or boiler, just in case you have a leak,, youd be asking for trouble lol
if u have now a 2 wire roomstat you can wire it up omitting the earth wire,, though a bit of knowledge on your side would be helpful... i am guessing you have 2 two port valves?
find the wiring centre and open it,AFTER YOU TURNED THE BOILER ELECTRICS OFF!!! here is what u need to do,,,
the...
competent electricians can carry out repairs on motoriasation OUTSIDE the boiler eg, roomstat,timer,cyl stat , 2 and 3 portvalves
as soon as you have to open the casing of the boiler you have to be corgi registered because you can compromise the integrety of the appliance, eg: damage the seals...
i had a couple of boilers where the bearing on the fan had gone,, the fan doesnt always get up to speed,so the pressure switch,,,, wont switch lol..
hope i didnt confuse you there,, get an engineer in ,, if hes halfway decent, he will find the fault
a slightly cheaper option is to install a 2 port valve linked with a cylinder stat running off a 240 v supply in the cupboard if you have one,, once the set temerature on the stat is reached the valve cuts the flowfrom the central heating to the cylinder preventing it from overheating though it...
i take your shower is above the bathtub? get a bathmixer with shower attachment and rail(between £40 and £80) the combi will give you better flowrate on the hotwater than any electric shower... :idea:
so many questions! by the sound o fit your water tank is at the same level as your showerhead?
1 (expensive option) is to fit a powershower with a negative head switch rather than on pressure differnce it will work on flow of water to turn the pump on,, the cheaper option might be an electric...
the outside stopcock is either... looking like a brasss cock with a handle you fint on an outside tap or.. a square kind of stump. both can be low in the ground up to 3 feet or so,, you can get a key for those at a plumbers merchand,,,the more modern cocks are hidden under some styrofoam in the...
the 1st stopcock was probably put in by waterboard? makes sense to open coldwater on sink(thats the minimum point where you are meant to have coldwater mains at)and then start turning the stopcock...when the water stops running from the tap.. u can be certain the mains is shut off,,, dont dare...
speed fit and similar (hep 2 o) can be used for heating and hot and cold water ,,,, weve done a pressure test on them and found that they break at about 45 bar lol not on the rubber but at the seams funny enuf,, just dont use them on gas!!!!!!!!!!!
here is a tip... the nut is at the radiatorside!so on the right you loosen the nut towards the wall and vice versa on the left(thats with the spanner at the northpole :lol: ) dont forget to hold the valve in place with a pair of adjustables or u might end up with an insurance claim for a ruined...
an easy and trouble free option is to change the syphon for a european style.. they don't require an overflow because any surplus water so to speak runs into the pan,, officially you will have to ask waterboard if you are allowed to install one though all new toilet cisterns are now fited with...