  1. C

    RCD tripping

    No USB sockets. Its a really old house and this section of electrics is really old! I have looked behind all sockets on the circuit and there is nothing obviously wrong - no loose connections etc. Andy, can you please explain in a little more detail? This is baffling me! Any advice...
  2. C

    RCD tripping

    As soon as you turn the CB for that circuit on, the RCD trips out. There is nothing on the ring main at all !
  3. C

    RCD tripping

    We have had a power cut in the area today and since then, I cannot get a ring main circuit breaker to stay on. The moment you flick the switch the RCD trips out. I have taken everything off the load and still the same problem. I have changed the CB and this is fine. Can anyone shed any...
  4. C

    Double socket sparking

    Of course not ! It’s turned off and need to get it sorted !
  5. C

    Double socket sparking

    Thanks for advice all. Will get a second opinion!
  6. C

    Double socket sparking

    It’s sparking behind the front plate. It looks as though it’s where the earth is connected. Could it be because there isn’t a tight earth connection ?
  7. C

    Double socket sparking

    Why would a double power socket start to spark? There is no load on the socket. The wiring is very old and has no earthing so have earthed the socket plate to the metal back box. Have checked connection for both L and N and seem to be ok. Any ideas please.
  8. C

    New member needing advice

    Can I connect another cable to the new PIR sensor for a switch? eg: wire at sensor and connect to switch?
  9. C

    New member needing advice

    I have tried connecting a similar IP rated switch. Its hard to know what is neutral - switched live etc as cant see other end of cables. I know blows at CU aren't good but this is really frustrating me. I don't own a multimeter - yet. Not sure which wires to go where with a neon switch...
  10. C

    New member needing advice

    I tried most combinations with a few blows from the consumer unit. brown to com and either black or grey to L1 didn't blow but I couldn't get the lights working! I obviously cannot see how original wires have been connected as out of reach. So frustrating but thanks for help so far....
  11. C

    New member needing advice

    Hi all. Nice to be here. I am a newbie to this site and a recently new to electrics. I have come across a problem - which I think should be simple - but it is baffling me and I can't understand what I am doing wrong. I am hoping that some kind knowledgeable person on here can help! I am...