    SMELLY SINK...VAPOUR?

    Hi there I've been told that the smell sink problem I've encountered could be due to VAPOUR and the trap not being man enough. Could one of you guys help me and tell me how to cure the problem please? Also, I think the sink waste eventually flows into a soil pipe a few metres away, could that be...
  2. M

    Fumes from Vokera boiler

    Thanks guys but just to clarify, there are 2 holes and nuts, should they both be securely closed? Thank you
  3. M

    Fumes from Vokera boiler

    Thanks Dave...there are two holes and nuts right? Both should be done up?
  4. M

    Fumes from Vokera boiler

    Hi there a firm I do maintenance work for asked to come and take a smell in their kitchen It smelt of gas fumes. When I looked at the top of the boiler at part of the flue assembly there were two brass hexagonal headed screws. One was screwed tightly in the other completely out. Should this...
  5. M

    Radiator with 3 15mm pipes connected?

    Dear Onetap and others who replied, many thanks again. I've had another look and on the other side of the stud wall is indeed an automatic vent (the type you normally see in the airing cupboard?). Do I need to replace this when I change the rad or can I do away with it? Many thanks Stuart
  6. M

    Radiator with 3 15mm pipes connected?

    Thanks for that guys, there is definitely an f & e tank so I'll check to see if it does loop over. Thanks again Stuart
  7. M

    Radiator with 3 15mm pipes connected?

    Hi there I have a radiator in an attic room that is cracked and needs replacing. Seems straightforward enough except that in addition to the 2 usual pipes at the bottom of the rad there's an extra 15mm pipe connected to the top of the rad which seems to be connected to the bleed valve?? Do I...
  8. M

    No cold upstairs

    Thanks for the reply, however the only pipes coming from the cold water tank appear to be for the pumped shower which works fine. The tank is definitely re-filling.Also the cold water tank contained quite warm water last night! Any other ideas? many thanks Stuart
  9. M

    No cold upstairs

    Sorry what a fool! there is no cold whatsoever upstairs!!
  10. M

    No cold upstairs

    Hi there pls help! I believe the upstairs cold supply to bath basin and cistern is mains as it looks as though the pipe work rises from the stopcock/kitchen sink area. The water in the storage tank was quite warm last night. Any ideas pls? Thanks in advance Stuart
  11. M

    Thermostatic shower not getting hot enough

    Sorry also the mixer is a £99 job from Wickes (now discontinued I believe)
  12. M

    Thermostatic shower not getting hot enough

    Hi there thanks for the reply. There are separate supplies the cold had a tap on it and I turned it down. The shower became hotter but the flow was slower
  13. M

    Thermostatic shower not getting hot enough

    Hi there could anyone help me to work out why a thermostatic mixer shower fed by mains cold and tank hot isn't getting as hot as it used to. I've tried turning the cold pressure down a bit but then the entire shower pressure is not great. Any ideas please? Thanks in advance
  14. M

    Half a bath of hot water

    Thanks for that, I'll give it a shot
  15. M

    Half a bath of hot water

    Hi there it's a direct combi water heater with off peak and peak elements. Do you think the lack of hot water is due to one faulty element? any ideas Many thanks in advance Stuart
  16. M

    CAN'T DRAIN SYSTEM

    Thanks for all that info everyone. So just to be be clear, I simply have to undo the screw in the picture which will let air out of the system, then the pipe going into the radiator should not spurt water when I undo it??
  17. M

    CAN'T DRAIN SYSTEM

    Thanks for all your help as usual guys have a good day Stuart
  18. M

    CAN'T DRAIN SYSTEM

    Thanks for that, I'll give it a try. One thing, I did find a filling loop upstairs in a cupboard, but it doesn't appear to have a drain cock on it but if you can fill system from it you must be able to drain??
  19. M

    CAN'T DRAIN SYSTEM

    Sorry, it's a combi (heats water and rads and no hot water cylinder?)