Search results

  1. A

    Glow worm beta com 30 heating problem

    Nope still the same ...running at between 30-40 degrees
  2. A

    Glow worm beta com 30 heating problem

    Ok done that gauze didn't seem bad and when I opened flow and return one at a time get a good flow back with cap removed ....wait and see now
  3. A

    Glow worm beta com 30 heating problem

    Ok great will check ...will I have to drain down boiler or can i isolate as yes it's on the right but only a small blue tap before filter and not after
  4. A

    Glow worm beta com 30 heating problem

    Hi yes it's a c model . I took the top of the mag filter didn't seem too dirty is there a built in filter on this model as well.
  5. A

    Glow worm beta com 30 heating problem

    Hi I moved into a flat that has a beta com 30 installed and straight away had problems with the heating. The boiler fires up ok and temp will go to 80 then after a few minutes the boiler cuts off as if it thinks the flat is up to temp which it isn't even when leaving heating on for five hour the...
Back