    Trying to work out what to do with central heating.

    The above is not a Sundial C plan.
  2. G

    4 way fittings

    Heating pipework (flow/return) are usually installed in close proximity to one another so it would be a tad difficult to use a cross tee, same applies with potable pipework (hot/cold), back in the day pipework was installed within notched joists so the use of a cross tee would foul the pipe...
  3. G

    Is my timeswitch faulty?

    If you took the above photo @ 5.07 am then the clock is correct. Assuming the photo was taken @ 17.07 then the clock is either 12 hours fast or 12 hours slow.
  4. G

    Johnson and starley

    The overheat stat would activate on the Circulator (Janus) and interrupt the pilot light.
  5. G

    Johnson and starley

    Unless the feed to WC has been taken from the cold feed to cylinder (teed off @ lowest point). The cylinder would be the direct type if coupled to a Janus. The CWSC is possibly slow to fill in which case the WC cistern ran the cylinder dry (no gravity circulation through the Janus).
  6. G

    Johnson and starley

    Never heard so much gobbledygook. Can’t make head nor tail of it.
  7. G

    Unvented pressure release into sink waste pipe - smelly

    Complete lash-up. I would imagine the installer doesn’t hold a G3 ticket.
  8. G

    combi v system

    You tell me.
  9. G

    combi v system

    So you required a “full screen” in order to ‘clearly see’ that the manometer tube was connected to the burner pressure test point as opposed to the inlet/working pressure test point which is located to the left side of gas valve? Lol what a fool.
  10. G

    combi v system

    It clearly wasn’t “working pressure” but “burner pressure” that they were measuring on that Potterton Profile. The inlet/working pressure on that Potterton Profile would of also shown >21mb. Do you not know the difference between the burner pressure test point and inlet pressure test point on...
  11. G

    combi v system

    The working principle of the zero/1:1 governor does NOT “draw the gas through the pipe” as stated above. Fan pressure whether negative or positive acts upon a diaphragm (offset) and in turn regulates the volume of gas to burner/mixing chamber by bleeding-off pressure to the underside of working...
  12. G

    combi v system

    Ian Puddick MD of the London Boiler Company also boiler expert to BBC, ITV & C4. Well well well, you couldn’t make it up.
  13. G

    combi v system

    Fixitflav & hard-work clearly show their incompetence when discussing gas related topics. The YouTube video clearly shows the manometer measuring the gas burner pressure and not gas working/inlet pressure on the Potterton Profile boiler. The 3 bods in that video are a bunch of clowns (I...
  14. G

    Soldering quality concern

    Ball-ache when trying to insert a tool in order to remove a stuck DOC washer, the other being the seating is not visable. Magnetite/debri will collect on the seating causing a blockage when opening the DOC, considering a tool can’t be inserted in order to clear the blockage then.....
  15. G

    Soldering quality concern

    Absolute mess. Best place for that pipework is in the scrap bag. “Wiggle room”?...that’ll be a shed load of wiggle room required to straighten that atrocity.
  16. G

    Intergas boiler

    Sorry but I don’t understand the above. I don’t understand this either. What point are you trying to make? Replacing a pump that is not integral to boiler and/or clearing a system blockage is a moot point as to whether the appliance is safe to use or not. Advice on the installation of nest etc...
  17. G

    Greenstar ri on y plan ....nest Nest

    Although the OP didn’t ask for an explanation on the working principal of the Y plan/Nest. Does the principal of the Sundial Y plan change when installing the Nest/Hive?
  18. G

    Greenstar ri on y plan ....nest Nest

    The above must be the worst explanation written on the working principal of a sundial Y plan system.
  19. G

    Tidy Plumbing / good job?

    Tundishes not pushfit.
  20. G

    Two zone Central heating How to use HIVE and wired thermostat??

    Use either a relay or switch the pump via the brown core of MV.