Search results

  1. D

    Adjusting blade alignment on a performance FMTC1500TK table saw

    To find a solution I visited other sites and the worst remark for this saw and indeed other products from the P range was on quality. I will not repeat the comments here. Being bit of a hoarder I decide to take the saw apart to see if anything was worth saving. I removed the legs and turned the...
  2. D

    Adjusting blade alignment on a performance FMTC1500TK table saw

    Sorry if I am causing confusion by not knowing technical terms, there are 2 groves or slots in the table top, one each side of the blade that the mitre guide runs in and the fence seems to be aligned to, and can be used to guide sledges,no riving knife?. The blade is not running parallel to...
  3. D

    Adjusting blade alignment on a performance FMTC1500TK table saw

    The old blade appears to be slightly thicker than the riving knife, the new blade about the same thickness. I want to align the new blade so that it is parallel to the groves in the table, but there is no obvious adjustment method. Nothing is mentioned in the handbook about alignment of blade...
  4. D

    Adjusting blade alignment on a performance FMTC1500TK table saw

    I know its a low end tool ex B&Q and blade supplied already installed was a bit out of alignment but it served me well for my needs in the past. I have replaced the blade with a finer blade and would like to calibrate the blade for the finer work but i can find no means of adjusting which is...
  5. D

    time limits for council action.

    Hi Woody It seems to me that wherever one looks at planning and building regs. a contradiction can be found within the frame work? The problem is nothing is clear cut leaving councils with lots of loop holes and varied opinions in interpretation of the planning frame work and their own...
  6. D

    time limits for council action.

    Thanks all for your replies, I hope this answers the questions you have raised. I have researched the history of this building, the building was bombed during ww2, partially demolished and rebuilt post war. The grading came later as a block grading of 5 houses, the grading description states the...
  7. D

    time limits for council action.

    A family member recently purchased a grade 11 flat, in the planning office archived files of 20 yrs ago photos of the flat/house can be found which shows the house was fitted with upvc windows. Also in the same file there are later letters to conveyancing solicitors stating there are no...
  8. D

    Spinning Cowl

    Thanks for all your replies, Foxhole, the small birds came down the chimney when the fireplace was an open fire with dish type cowl on the chimney pot. The current problem is the spinning cowl fitted when the wood burner was installed, has stopped spinning, I assume this stops or restricts the...
  9. D

    Spinning Cowl

    Hi. I would be pleased of any advice that can be given. Last year I had a wood burner fitted complete with a spinning cowl on the stack to cure down draft and wall vented to the outside at the back of the stove via permanent open vent. Building inspector approved. The down draft is caused by...
Back
Top