Search results

  1. S

    Bathroom underfloor heating - is this possible?

    Our Bathroom has a concrete floor with underlay and carpet, we'd like to install electric underfloor heating but not raise the floor height too much, if at all. On that basis, we thought a karndean type flooring might work, certainly if combined with the foil type electric underfloor heating...
  2. S

    Gledhill boilermate 1 - boiler pump running all the time?

    System hasn't been running properly for a few months ago, I put this down to replacing two normal sized rads with a full height vertical rad and maybe the system couldn't manage the new heating demand. However, I realised last week the boiler pump wasn't running at all. Traced the problem to...
  3. S

    240v portable generator - industrial socket to domestic?

    I have a honda petrol generator that in my last home was connected to the house circuit and could be used during power cuts - there was a manual switch next to the consumer unit that was used to switch over the circuit to the generator. The generator only has industrial type 240 v sockets...
  4. S

    Best product to bond an undermount composite sink to quartz

    Anyone help with this, is it just a general bonding silicon, or are there specialist bonding products specifically for bonding composite to quartz? I've also been advised to build some form of wooden support under the rim of the sink to help keep the sink secure - any advice welcomed, thanks.
  5. S

    Camray 3 efficiency?

    I was on the verge of changing out my camray 3 for a grant condensing boiler, but following it blowing the door open after a failed start, I had it serviced. The chap who serviced it said it wasn't really worth changing it out as the camray tested at 90.3% net efficiency and 85% gross. Also...
  6. S

    Camray 3, door blown open and boiler tripped

    Just gone into my garage and realised the boiler has tripped and the cabinet door has blown open - at least that's what it looks like. The insulation around the boiler has been disturbed as well that suggests theres been some sort of pressure build up within the cabinet? I've reset it and its...
  7. S

    15 to 21kw or 21 to 26kw boiler?

    Looking to replace my oil fired Camray 3 70/90. Output of existing boiler is 20 to 26 kw. The Grant Vortex range have an ECO Utility model that has a range of 21 to 26kw, but they also have a Pro Utility that does 15 to 26kw. The boiler is in my garage and it powers a 250 litre heat store...
  8. S

    15 to 21kw or 21 to 26kw boiler?

    Looking to replace my oil fired Camray 3 70/90. Output of existing boiler is 20 to 26 kw. The Grant Vortex range have an ECO Utility model that has a range of 21 to 26kw, but they also have a Pro Utility that does 15 to 26kw. The boiler is in my garage and it powers a 250 litre heat store...
  9. S

    Domestic wiring question - outside lights

    We've 3 outside lights on our house, single switch operates all 3. They need replacing - this I can manage. However, is it possible to add a 4th light just by tying it into one of the existing lights? It would be approx 4 foot of cable, it's just around the corner of the house, or does it need...
  10. S

    Riello 40 - changing motor, fan seized onto shaft

    Hi, went to replace the motor on my Riello 40 and I'm struggling to get the fan off the shaft. Removed the grub screw but no joy, tried release oil and even warming the fan hub with a blowtorch. Applied as much pressure as I could without damaging anything. Anyone have any tips or know where I...
  11. S

    Halogen light transformer reqd (fits in ceiling rose)

    It's manufactured by Anchorn, model number is AET-3202CT. 240v to 12vdc and it looks (and size) a bit like a ceiling rose with a 12 mm hole through the centre for the cable. It fits inside the cover of a ceiling light. Anyone seen anything like this or know where I can get one? Thanks
  12. S

    Oil Fired Camray 3 - what to replace with?

    Posted this last winter //www.diynot.com/forums/viewtopic.php?t=40787&highlight=camray+3 Seemed to be fine after the above. Had it serviced about a month after the above and now it's started the same again - cleaned filter again but this time it doesn't want to sort itself, there...
  13. S

    Oil Fired Camray 3 lockout

    Recently moved to a new house and it's fitted with an oil fired Camray 3. Not sure of it's last service, suspect it's approx 8yrs old as house was converted the. The unit looks like it's been well looked after as everyhing is spotless. Today the lockout light came on, reset and away it went. The...