Search results

  1. T1GERIII

    Ring Doorbell Alternative

    Eufy doorbell no subscription
  2. T1GERIII

    Scantronic 9448+ all brands of sirens compatible?

    Any brand will work; recommend pyronix delta bell easy to connect
  3. T1GERIII

    pyronix manual and Qs

    Change engineer code- Enter engineer code, press no until it says change codes press yes on that Then yes again Followed by no until it says change engineer code press yes Press C to clear existing Enter new code followed by yes Press no until it shows CHANGE CODES again. press A to save and exit
  4. T1GERIII

    pyronix manual and Qs

    Change master code - press D , enter your master code press no until it asks to change codes or edit users. Press yes on that then no until it says change master code. Press the C button to clear existing and then type New code followed by the yes button. Press no until it says change codes/edit...
  5. T1GERIII

    Changed WIFI router for hikvision -how to reconnect so hikvision app works?

    As Sparky said, wrong IP range possibly gateway set for old router IP on a different range. Enable dhcp then disable.
  6. T1GERIII

    ew002lcdg-2 eurosec alarm can't set low batt fuse

    Post picture of the main panel inside the house
  7. T1GERIII

    Trying to disconnect zone from Paragon Super II

    Correct, that is the fuse carrier for the panel
  8. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Engineer code > zone number ( I.e 02) > yes/enter > 00 Not used > enter > back to installer mode > 99 enter escape installer mode
  9. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Remove zone wiring and power to the sensor from aux 12v and 0v. Enter installer mode and disable zone in programming.
  10. T1GERIII

    Pyronix Euro46 Zone setting

    Level set - If ‘Yes’, the system becomes ‘level set’ (having one area set only at any one time). If ‘No’: The system becomes an ‘area’ system (fully independent areas).
  11. T1GERIII

    Pyronix Euro 46 v10

    private messaged
  12. T1GERIII

    Scantronic 9751 rewiring, house refurb

    I’d guess your top 3 cores then the lone 12v + and -. Best bet would be to trace the O/P cores I labelled as bell that will lead you to the others for certain.
  13. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Bell will only sound for 15-20mins if the battery inside it is still healthy once the power to it is removed
  14. T1GERIII

    Scantronic 9751 rewiring, house refurb

    Ignore the bell. Remove the zone cabling to the pirs you wish to re-route Remove the 12v 0v feed for them Re-route and put back as they were Exit engineers mode
  15. T1GERIII

    CCTV networking

    TP Link power line adaptor
  16. T1GERIII

    CCTV manufacturers with user manuals ?

    The end user would receive an instructed handover from the installer on the use of the system and application chosen it’s not a one app fits all so manufacturers can’t provide you with that
  17. T1GERIII

    Pyronix Euro 46 v10

    Private messaged you
  18. T1GERIII

    No fused spur

    YeeHawwwww!
  19. T1GERIII

    CCTV manufacturers with user manuals ?

    Hikvision website has all user manuals pdf and firmwares if required https://www.hikvision.com/uk/products/