  1. S

    Hot water from expansion pipe

    Have now made new loop on vent pipe ,now 40cm above F/E CISTERN also checked for any ferrous on pipe . nothing sticking to magnet. water still coming from expansion pipe.
  2. S

    Hot water from expansion pipe

    Already replaced F/E pipe-work. Pump is 7 yrs old and yes I do have sds
  3. S

    Hot water from expansion pipe

    it is raised above the F/E cistern then into a U into cistern
  4. S

    Hot water from expansion pipe

    best way i can explain it is: the arrow on pump is going towards three port valve approx 2 ft. The feed and vent pipes are approx are two ft before entering pump.
  5. S

    Hot water from expansion pipe

    yes they are both fine.
  6. S

    Hot water from expansion pipe

    Have tried turning thermostat down on boiler before. Have noticed as soon as boiler fires up from cold, water almost immediatly starts to come from expansion pipe on F/E cistern
  7. S

    Hot water from expansion pipe

    just checked it and still hot clear water at a rate of one litre a minute on speed 1 from pump. Level on F/E cistern still staying same.
  8. S

    Hot water from expansion pipe

    but if was cylinder coil the water would rise in F/E cistern, which it never does. Also water storage tank and F/E cistern same level. Tht water only flows from expansion pipe when heating and water turned on
  9. S

    Hot water from expansion pipe

    the first pipe from pump flow is to three port valve. By the way thanks for your time :wink:
  10. S

    Hot water from expansion pipe

    pumping away from feed and vent
  11. S

    Hot water from expansion pipe

    feed and expansion pipe are within 150mm of each other
  12. S

    Hot water from expansion pipe

    Have turned pump to 1 setting. Water still flowing same amount from expansion pipe
  13. S

    Hot water from expansion pipe

    The water from expansion pipe is never reaching overflow pipe. Seems to be recirculating from the F/E cistern. Boiler is approx 3ft below the F/E cistern and 10 ft away from airing cupboard to which the F/E cistern is above. Pump is connected right way round and the F/E cistern feed and...
  14. S

    Hot water from expansion pipe

    Hi, could anybody advise me. I have hot water coming from expansion pipe to expansion vessel. It never overflows and pump is on 2nd setting. Recently had boiler moved from kitchen to upstairs. Have had powerflush. Does header tank need to be positioned higher in loft? at present on floor to...