Search results

  1. D

    Reinstate decommissioned PIRs

    The wires in the Steinel are black, blue and brown. I have old 3c & e coming from the house supply and then on to the lights. Have connected Steinel brown with yellow 3 core, Steinel blue with blue 3 core and Steinel black with 3 core red as per the previous image. Finally got it working -...
  2. D

    Reinstate decommissioned PIRs

    Thank for replies. I checked all switches and lamps and wiring was fine. Just seen an extra PIR on other side of house which had the switch live wire (yellow) disconnected, so I reconnected and the lights are on. Problem is, now they don’t turn off - they are on when the override switch is on...
  3. D

    Reinstate decommissioned PIRs

    This is the intermediate switch that controls the lights - red wires connected together and blue and yellow into the switch.
  4. D

    Reinstate decommissioned PIRs

    Hello all, newbie here. Just moved into a house that has 4 x outside lights connected to 4 x PIRs. At some point the PIRs were decommissioned by the previous owner so the lights are only controlled (on or off) by the 3 x interior light switches. I want to reinstate the PIRs so that when the...