    Replace TP5 with Vaillant 380f - wiring question

    Yes - the 24v RT bridge which is definitely needed ( I tried it with and without) I thought he was talking about the burner off bridge, my mistake.
  2. S

    Replace TP5 with Vaillant 380f - wiring question

    Just checking the manuals - the only time I can see the burner off bridge is removed is when setting a ceiling temp. for underfloor heating thermostat. I am going to leave as is for now.
  3. S

    Replace TP5 with Vaillant 380f - wiring question

    Now the wait symbol is gone ( I lowered the thermostat by one degree) boiler all quiet, no boiler, no pump - in fact if it wasnt for display, I would think it was off at the wall.
  4. S

    Replace TP5 with Vaillant 380f - wiring question

    Just the waiting symbol flashing - egg timer. thermostat not callin for heat.
  5. S

    Replace TP5 with Vaillant 380f - wiring question

    mmm..its... its off now (no burner or pump) and the red link is still there - in fact its always been there - even with the danfoss TP% connected... ???
  6. S

    Replace TP5 with Vaillant 380f - wiring question

    Worked it out now - all seems to be running ok Procedure as follows Boiler off at mains open boiler, disconnect existing thermostat connections at PCB (two wires one 230v mains, other RT) run new heat resistant 0.75 two core to ebus, connect to sender receiver mounted in boiler cupboard REMOVE...
  7. S

    Replace TP5 with Vaillant 380f - wiring question

    It would end up like this. the black and grey currently to to the purple RT and live. the pic was downloaded from elsewhere
  8. S

    Replace TP5 with Vaillant 380f - wiring question

    Sorry - its a Vaillant Sensohome VRT 380f
  9. S

    Replace TP5 with Vaillant 380f - wiring question

    Thanks Chris, Yes it has the possibility of plugging on but only on boilers with a socket! the ecotec plus 831 doesnt (as far s I can see) so it will need wiring separately. the control unit is RF
  10. S

    Replace TP5 with Vaillant 380f - wiring question

    I have a Vaillant Ecotec plus 831 with a Danfoss TP5. The electrical connections are via a five core cable. I believe three (live netural and earth are mains supply and the other two to Danfoss) I want to wire in a Vaillant 380f wireless and believe that is simple - 2 wires from EBUS to new...