Search results

  1. M

    Scantronic (8136) - set/unset via a zone

    ok, done using ESPHome, 2 relays, 2 inputs Keyswitch on zone 13 (relay) Normal alarm on zone 14 (relay) OP3 configured to latch when alarm active OP4 configured to latch when alarm set I found a new document called Installation and Programming Guide for the 8136UK-50/75 which helped...
  2. M

    Scantronic (8136) - set/unset via a zone

    Thanks, what is the A/T 1 connection in your picture?
  3. M

    Scantronic (8136) - set/unset via a zone

    Typing my alarm code in during this process performs an unset..confusing!
  4. M

    Scantronic (8136) - set/unset via a zone

    Bit of progress, if I set the zone to KF rather than KM. Then completing the circuit on the zone now puts the alarm (Level A) into a kind of set mode, but the sounder maintains a steady tone, and it never completes the set.
  5. M

    Scantronic (8136) - set/unset via a zone

    Thanks, my model is 8136 which doesn't have this bit in the manual. The KM doesn't seem to exist in an area (see the photo above where I configure the zone). however, I do have a keyzone setting on the levels now (I think this is new). See attached :)
  6. M

    Scantronic (8136) - set/unset via a zone

    U00:A03:RESET U00:A02:RESET U00:OFF SITE Is the latest in the log for today when I touched the wires. Alarm zone 1 on the main board.
  7. M

    Scantronic (8136) - set/unset via a zone

    This is how it looks on the keypad when configuring zone 1. I'm simply connecting the circuit together using a wire between the two terminals to simulate a key switch/relay
  8. M

    Scantronic (8136) - set/unset via a zone

    Yup. Problem is though, my alarm system doesn't seem to do anything when the zone in in KM mode, and I open/close the zone circuit.
  9. M

    Scantronic (8136) - set/unset via a zone

    Yes. So it seems that I can configure a zone as a KM which I (google) interpret as Keyswitch Momentary. So If I close/open a circuit on the zone configured as KM, I would expect the alarm to set/unset (assuming no alarms, errors etc). Does that seem right?
  10. M

    Scantronic (8136) - set/unset via a zone

    Hi, I'm trying to make a Scantronic alarm a bit smarter, and wonder if there is a zone type that would support setting/unsetting the alarm via a zone (rather than via the keypad). I believe there is some kind of key switch (KM zone type?) that is possibly compatible, but ideally I just want to...
Back