Search results

  1. D

    Mira Sport Max. Low Flow Problem.

    Problem eventually solved. I was delayed in getting it sorted by a couple of other issues by which time the shower was not operating at all. I tested the solenoid coil & sure enough, a zero reading. Replacing the coil was a simple enough task. To be honest, my major difficulty was removing the...
  2. D

    Mira Sport Max. Low Flow Problem.

    Yes, the reading should be 3.5K ohms. Sorry for any confusion.
  3. D

    Mira Sport Max. Low Flow Problem.

    Thanks for your reply. I'm confident that the water pressure is not the cause of the problem. The shower operates normally for a few minutes then the water cuts off completely & the low flow light comes on. There is no variation in flow rate or temperature prior to cut off. I've already replaced...
  4. D

    Mira Sport Max. Low Flow Problem.

    Thanks to those who have replied however, I did make it clear in my original post that the obvious options have been eliminated. The shower head & hose are in perfect condition & the water pressure is fine. Electric shower low flow faults are frequently caused by solenoid problems. I'd encourage...
  5. D

    Mira Sport Max. Low Flow Problem.

    I have a Mira Sport Max 10.8kw shower which is about 12 years old. It gets used briefly once a day so it has not exactly been flogged to death. I replaced the thermal cut-out switch a couple of years ago after an earlier fault. Recently the shower has started cutting out after a couple of...
Back