    Gloworm Fuelsaver Complheat 65 Burner Problem

    Don't have a flame sensing electrode. Will check if live across the main gas solenoid black and blue cables. Otherwise it must be the PCB. Have good contact electrode lead/ connection. Power to pilot solenoid OK Pilot ignites when cold Ignition spark switches off and main gas...
  2. M

    Gloworm Fuelsaver Complheat 65 Burner Problem

    Raden, what spark gap you talking about? maco
  3. M

    Gloworm Fuelsaver Complheat 65 Burner Problem

    Is the PCB suppose to arc? maco
  4. M

    Gloworm Fuelsaver Complheat 65 Burner Problem

    I've noticed arcing across the PCB when ignition is sparking. Need to check electrode lead/connection for poor connection.. Otherwise it'll have to be a replacement PCB ! :cry: maco
  5. M

    Gloworm

    I had the same problem with my gloworm fuelsaver boiler. Pressure was at 1 bar but red warning light was indicating ch low pressure. Fixed the problem by removing LP switch and cleaning the **** and sludge out from the hole where the LP switch screws into. Hope this helps maco
  6. M

    Gloworm Fuelsaver Complheat 65 Burner Problem

    Gloworm Fuelsaver Complheat 65 / Unvented Hot Water Cylinder Hi Can you shed some light on this problem. The Boiler will function for 1 hr from cold, heating the rads and hot water. After this time when the boiler needs to 'fire up' the PCB neons will only light to number 3, number 4...
  7. M

    Glow worm lockout

    Thanks Tony, Hopefully the LP switch will reset itself. The boiler is on and I'm keeping a watchful eye on the pressure gauge! If I do need to clean the LP switch and sundry would I infact have to drain the CH system? thanks again Maco
  8. M

    Glow worm lockout

    Thanks for the input corgiman. There's a live feed going to the low pressure switch but non comming out. After isolating the switch the pcb works fine and the boiler fires up first time. Think perhaps your right the switch is faulty or perhaps have a massive airlock in system. Is this...
  9. M

    Glow worm lockout

    I have a Glowworm Fuelsaver Complheat 65, age unknown. I needed to isolate and remove a radiator from the living room whilst decorating. After completion the radiator was replaced and rad valves opened. Unfortunately it seems that I forgot to top up the system, and as a consequence after a day...